Service Connection - Blodgett SN-3E Installation, Operation And Maintenance Manual

Blodgett corp. electric convection steamer installation, operating and maintenance instruction sn-3e, sn-5e
Hide thumbs Also See for SN-3E:
Table of Contents

Advertisement

SERVICE CONNECTION

ELECTRICAL CONNECTION: Ø1 1/8" hole for electrical connection. Rating to be as specified on data plate.
DRAIN: 1"IPS to open floor drain. No solid connection. Use copper only, 24" length before open air gap opening (No bends or elbows).
GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
C
WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF WATER
QUALITY, CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANALYZED. YOUR WATER SUPPLY MUST BE
WITHIN THESE GENERAL GUIDELINES:
TOTAL DISSOLVED SOLIDS
TOTAL ALKALINITY
SILICA
CHLORINE
pH FACTOR
WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
DIMENSIONS ARE IN INCHES [MM]
20 [508]
WATER QUALITY STATEMENT
LESS THAN 60 PPM
LESS THAN 20 PPM
LESS THAN 13 PPM
LESS THAN 1.5 PPM
7.0-8.5
ELECTRICAL CHARACTERISTICS
17 [432]
27.5 [698]
1.75 [45]
1.13 [29]
OPTIONAL LEGS
4
1/2-NPT DELIME INLET
4 [102]
23.5 [597]
2 [51]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sn-5e

Table of Contents