Download Print this page

Service Connections - Blodgett SB-10E Installation, Operation And Maintenance Manual

Blodgett corp. installation operation maintenance manual convection steamer on an electric boiler base sb-6e, sb-10e, sb-16e
Hide thumbs Also See for SB-10E:

Advertisement

1.0 SERVICE CONNECTIONS

ELECTRICAL CONNECTION: Rating to be as specified on data plate.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)
S
STEAM TAKE-OFF CONNECTION: 3/4"IPS optional to operate adjacent equipment.
DRAIN: 2" IPS piped to open floor drain. No Solid Connection.
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Available kW
MODEL
STD.
SB-6E
24
SB-10E
36
SB-16E
42
DIMENSIONS ARE IN INCHES [MM]
S
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED Ø
WATER QUALITY STATEMENT
Total dissolved solids
Total alkalinity
Silica
Chlorine
pH Factor
OPT.
kW
PHASE
36, 42, 48
24
3
42, 48
36
3
48
42
3
48
3
S
18 [457]
(36" CABINET)
8.75 [222]
S
2.75 [70]
3.5 [89]
28 [711]
23 [584]
16.75 [425]
8.75 [222]
6 [152]
5.75 [146]
0 [0]
SB-6E & SB-10E TOP VIEW
7/16" [11mm] HOLES ON 2.5 [63] B.C.
Less than 60 PPM
Less than 20 PPM
Less than 13 PPM
Less than 1.5 PPM
7.0-8.5
ELECTRICAL CHARACTERISTICS
AMPS PER LINE
208V
220V
240V
66.6
63
57.8
99.9
94.5
86.6
116.6
110.2
101
N/A
126
115.5
24 [610]
4.5 [114]
2.5 [64]
4
380V
415V
480V
36.5
33.4
28.9
54.7
50.1
43.3
63.8
58.4
50.5
72.9
66.8
57.7
36 [914]
18 [457]
3.5 [89]
2.5 [64]
SB-16E TOP VIEW
600V
23.1
34.6
40.4
46.2

Hide quick links: