7. FLUSH CYCLE: Turn main power switch to ON. When READY light comes on, turn
main power switch to OFF to flush generator. Repeat this step three times to
completely flush generator.
8. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean
cloth. Dry with soft cloth. Leave compartment door open when not in use.
The steamer is now ready for use. Turn off for overnight shutdown.
6.0 ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS
The steamer has been factory set so that when it is ON and in the READY mode, it will
maintain water temperature in the steam generator tank at approximately 205°F (just
below water boiling point). However, for high altitude locations, an authorized servicer
must adjust the steamer temperature lower. To adjust:
1. Remove side panel and turn control panel power switch to ON.
2. Open compartment door, and after about 5 minutes, steam will be seen, entering the
cooking compartment.
3. Turn thermostat shaft counter clockwise to lower temperature until steam just ceases
to enter cooking compartment and READY light goes on.
4. Replace side panel.
5. Follow TESTING PROCEDURES in this manual.