RWP Weighing Indicator Technical Manual(v1.16)
Warm-up time of 15 minutes stabilizes the measured values after
switching on.
Calibrate with exact calibration weights, minimum 1/3 of the scale capacity
want to use for calibration. For calibration see details in parameter.
Then you can start your operation
Load cell connections
Connect Adaptor and Charging
To charge the battery insert the adaptor pin to jack. Adaptor simply plug into
the mains power. The scale no needs to be turned on.
The battery should be charged 12 hours for full capacity.
The symbol status of the battery
Battery voltage has dropped
Low voltage
Fully charged
.
Do not use any other type of power adaptor than the one supplied with the
scale.
Verify that the AC power socket outlet is properly protected.
Note: Please charge the battery before using the scale for the first time.
Connect the load cell cables to the terminal as shown below.
5Pin
Connection
Pin 1 Signal +
Pin 2 Signal -
Pin 3 Shield
Pin 4 Exc -
Pin 5 Exc +
It can connect four 350 ohm load cells.
The load cell drive voltage is 5V DC ±5% between
Excitation + and Excitation -.