TW20_NS20_EW20 Series Weighing Indicator Operation Manual

3. INSTALLATION

3.1 Unpacking

Remove the scale from the carton.
Remove the protective covering. Store the packaging and to use if you need to transport the scale later.
Inspect the scale for damage.
Make sure all components are included.
1. Indicator
2. Adaptor
3. Manual
3.2 Installation
Place the Indicator on a table or use indicator holder to connect with stand.
Connect the platform load cell cable in to the indicator load cell connector. Load cell connector is locating
back side of the indicator.

3.3 Load cell connections

Connect the load cell cables to the terminal as shown below.
It can connect four 350 ohm load cells.
The load cell drive voltage is 5V DC ±5% between Excitation + and
Excitation -.
 Connect the dual load cell cables to the terminal as shown
below.(optional)
9 Pin
1
2
3
4
5
6
7
8
9
Connection
Excitation +
Sense +
Shield
Sense -
Excitation -
NC
Signal -
Signal +
NC
7 Pin
Connection
1
Signal -
2
Signal +
3
Shield
4
Excitation -
5
Sense -
6
Sense +
7
Excitation +
- 10 -
REV:01
7Pin
Connection
Pin 1
Signal -
Pin 2
Signal +
Pin 3
Shield
Pin 4
Exc -
Pin 5
Sen -
Pin 6
Sen +
Pin 7
Exc +