T Scale RWP Technical Manual

T Scale RWP Technical Manual

Weighing indicator

Advertisement

RWP
Weighing Indicator
V1.16
REV:Y1,May 2016

Advertisement

Table of Contents
loading

Summary of Contents for T Scale RWP

  • Page 1: T A R

    Weighing Indicator V1.16 REV:Y1,May 2016...
  • Page 3: Table Of Contents

    RWP Weighing Indicator Technical Manual(v1.16) CONTENTS SPECIFICATIONS….………………………………………………….……..4 INTRODUCTION………………………………………………………………...6 INSTALATION …………………………………………………………………..7 Unpacking…………………………………………………………………..7 Installation…………………………………………………………………..7 Load cell connections..……………………………………………… ... 8 Connect Adaptor and Charging..………………………………………...8 DESCRIPTION……………...……………………………………………...9 Display……………………………………………………………………..9 Key board……………………………………………………………..…….10 OPERATION.…………………….………………………………….………….11 5.1. Power ON/OFF……………………………………………..………..11 5.2. Zero……………………..............11 5 . 3 . T a r e ..............1 1 5.4.
  • Page 4: Specifications

    RWP Weighing Indicator Technical Manual(v1.16) 1. SPECIFICATIONS Overall View Dimensions - 4 -...
  • Page 5 RWP Weighing Indicator Technical Manual(v1.16) Model Resolution 1/30,000 Indicator housing ABS Plastic Stabilisation Time 1 Seconds typical Operating Temperature 0°C ~ +40°C / 32°F - 104°F AC Adaptor (12V/500mA) / Power supply (external) Ni-MH battery (1.2V/2000mAh x 6) Calibration Automatic External...
  • Page 6: Introduction

    RWP Weighing Indicator Technical Manual(v1.16) 2. INTRODUCTION  The RWP series weighing indicator that amplifies signals from a load cell, converts it to digital data and displays it as a mass value.  It is suitable for general weighing or more specialized applications such as check weighing, animal weighing and accumulation applications.
  • Page 7: Instalation

    RWP Weighing Indicator Technical Manual(v1.16) 3. INSTALLATION Unpacking When you receive the scale, inspect it to make sure that it is not damaged and that all are parts are included:  Remove the Indicator from the carton.  Remove the protective covering. Store the packaging and to use if you need to transport the scale later.
  • Page 8: Load Cell Connections

    RWP Weighing Indicator Technical Manual(v1.16)  Warm-up time of 15 minutes stabilizes the measured values after switching on.  Calibrate with exact calibration weights, minimum 1/3 of the scale capacity want to use for calibration. For calibration see details in parameter.
  • Page 9: Description

    RWP Weighing Indicator Technical Manual(v1.16) 4. DESCRIPTION Display DISPLAY FUNCTION Check weighing ZERO Indicator for Zero display TARE Indicator for Tare display GROSS Indicator for Gross weight Indicator for Net weight STABLE Indicator for Display stability AUTO Indicator for Auto Accumulation...
  • Page 10: Key Board

    RWP Weighing Indicator Technical Manual(v1.16) Key Board FUNCTION Turn the power On/ Off Used to reset to Zero. In setting mode can use to confirm entry Used to recording tare values and change the value from gross value to net value.
  • Page 11: Operation

    RWP Weighing Indicator Technical Manual(v1.16) 5. OPERATION Initial Start – Up: Warm-up time of 15 minutes stabilizes the measured values after switching on. 5.1. Power ON/OFF: Switch on the balance by pressing key. The display is switched on and the test is started and if want to switched off, press again the key.
  • Page 12: Enter To Menu

    RWP Weighing Indicator Technical Manual(v1.16) It can set an upper or lower limit when weighing with the limits range. During the limit controls dividing the unit will indicate whether a value upper or lower limits with an alarm sound . For details see the parameter F3 oFF.
  • Page 13: Accumulation

    RWP Weighing Indicator Technical Manual(v1.16) bEEP Press key to enter, press key until display show Press key to enter, press Check mode 1 Check mode 2 Check mode 3 Select desired setting by pressing key and press key to confirm, press key to escape.
  • Page 14: Accumulation Automatically

    RWP Weighing Indicator Technical Manual(v1.16) Note: When you change the weighing unit this saved values will be clear. Accumulated Total Manually, the scale can be set to accumulation by pressing key , when an optional printer is connected. See details in F4 Prt.
  • Page 15: Backlight Setting

    RWP Weighing Indicator Technical Manual(v1.16)  Bring the load on to the platform.  When the load few seconds get stable, the reading will be locked for few seconds and will be follow beep.  It can add or remove loads also update the weighing locked values.
  • Page 16: Parameter

    RWP Weighing Indicator Technical Manual(v1.16) 6. PARAMETERS KEYS OPERATIONS INTO THE MENU Enter the menu  In weighing mode, press key and key together. Select the menu  Press key, it can change the menu block one by one.  Using increase the digit.
  • Page 17: Parameter Block

    RWP Weighing Indicator Technical Manual(v1.16) PARAMETER BLOCK Menu Sub-Menu Description Lower limit value SET Lo F0 H-L Weighing with Upper limit value. SET Hi set limits Clear the accumulation memory with out F1 toL to CLr printout Print the total accumulation memory and clear...
  • Page 18 RWP Weighing Indicator Technical Manual(v1.16) added To connect wireless wirel Set BAUD rate After setting the RS 232 mode, display will be shown current baud rate b XXX. Available baud rate: b600, b1200, b2400, b4800 and b9600 If necessary change the...
  • Page 19 RWP Weighing Indicator Technical Manual(v1.16) PROGRAM PARAMETERS Menu Sub Menu Description Auto zero point settings A2n 0 P1 ref 0. 5d 0 – auto P1 0 Zero setting range. When the display is turn on the scale is set to...
  • Page 20 RWP Weighing Indicator Technical Manual(v1.16) Linear calibration Linear Normal calibration nonlin Creep calibration Crpcal For Dual Range Settings Decimal point settings Deci Set the scale first increment Div 1 Set the scale second increment Div 2 Enter the scale first capacity...
  • Page 21: Calibration

    RWP Weighing Indicator Technical Manual(v1.16) 7. CALIBRATION Fo h-l  In weighing mode, press key and key together.  Press key continuous until display will be shown. prog  Press key, display will be shown.  Enter the password. Press...
  • Page 22 RWP Weighing Indicator Technical Manual(v1.16)  Enter the function by pressing key, display will be shown 05. 000 Currently adjustment  If want to change by using the keys keys to select the required setting  Enter the selected setting by pressing...
  • Page 23 RWP Weighing Indicator Technical Manual(v1.16)  Load the first calibration mass weight on the platform (mass weight should be1/3 of the max capacity) and wait few seconds for display stability. Load 2  Then press key , display will be shown ...
  • Page 24: Rs232 Out Put

    RWP Weighing Indicator Technical Manual(v1.16) 8. RS-232 OUTPUT RWP series scales can take out data through RS 232 output. Specifications: RS-232 output of weighing data Code : ASCII Data bits : 8 data bits Parity : No Parity Baud rate...
  • Page 25 RWP Weighing Indicator Technical Manual(v1.16) Print Out Formats Note: Lab 0 & 2 for English and Lab 1 & 3 for Chinese Language 2011/12/30 11:11 WEIGHT: 1.00kg WEIGHT: 1.00kg 2011/12/30 11:11 WEIGHT: 1.00kg WEIGHT: 1.00kg TOTAL: 1.00kg TOTAL: 1.00kg 2011/12/30...
  • Page 26 RWP Weighing Indicator Technical Manual(v1.16) 2011/12/30 11:11 S/NO: S/NO: NET: 1.00kg NET: 1.00kg GROSS: 1.00kg GROSS: 1.00kg TARE: 0.00kg TARE: 0.00kg 2011/12/30 11:11 S/NO: S/NO: NET: 1.00kg NET: 1.00kg GROSS: 1.00kg GROSS: 1.00kg TARE: 0.00kg TARE: 0.00kg TOTAL: 10.00kg TOTAL: 10.00kg...
  • Page 27: Drawing

    RWP Weighing Indicator Technical Manual(v1.16) 9. DRAWING - 27 -...
  • Page 28 RWP Weighing Indicator Technical Manual(v1.16) - 28 -...
  • Page 29: Error Codes

    RWP Weighing Indicator Technical Manual(v1.16) . ERROR CODES Error Message Description Solution Maximum load exceeded Unload or reduce weight ----- Incorrect date Enter the date by using format Err 1 “yy;mm:dd” Incorrect time Enter the time by using format Err 2 “hh:mm:ss”...
  • Page 30 RWP Weighing Indicator Technical Manual(v1.16) The company was founded in Taiwan in 1967 as Taiwan Scale Mfg Co., Ltd in order to produce Mechanical Weighing Instrument. Today, this privately owned company is recognized worldwide as a leading Electronic Weighing Scale Manufacturer.

Table of Contents