1.0 SERVICE CONNECTIONS

ELECTRICAL CONNECTION: 1-1/8" hole for electrical connection. Rating to be as specified on data plate.
DRAIN: 1"IPS to open floor drain. No solid connection. Use copper only, 24" length before open air gap opening (No bends or elbows).
GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)
CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)
C
WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF WATER
QUALITY, CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANALYZED. YOUR WATER SUPPLY MUST BE
WITHIN THESE GENERAL GUIDE LINES:
TOTAL DISSOLVED SOLIDS
TOTAL ALKALINITY
SILICA
CHLORIDE
pH FACTOR
WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
MODEL
kW
PHASE
SC-7E
17.5
3
24 - Std
3
SC-10E
30 - Opt
3
19.5 [495]
2.19 [56]
WATER QUALITY STATEMENT
LESS THAN 60 PPM
LESS THAN 20 PPM
LESS THAN 13 PPM
LESS THAN 1.5 PPM
7.0-8.5
ELECTRICAL CHARACTERISTICS
208V
220V
48.6
45.9
66.6
63
83.3
78.7
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED
Ø
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
1/2-NPT DELIME INLET
2.19 [56]
4
AMPS PER LINE
240V
380V
42.1
26.6
57.8
36.5
72.2
45.6
24 [610]
9 [229]
480V
21.1
28.9
36.1
1.75 [45]
3 [76]
3.94 [100]