6.3.1

Parameter settings of 1/1gang sensor/blind actuator

Actuator settings
Fig. 16:
Actuator settings
Sensor settings
Fig. 17:
Sensor settings
Product manual 2CKA001473B9187
Commissioning
[1] Changing the name
[3] Switching the actuator via the ∨ ∧ buttons
[2] Deleting the channel
[4] Selection of the type of actuator for
optimizing the behaviour during different
events.
Selecting the function:
Blind actuator
Roller blind actuator
Roof window actuator
Awning actuator
[5] Button "Calibration"
A wizard guides you through the
calibration process.
[6] Setting the movement time up/down in
seconds via the -/+ buttons
[7] Setting the time in milliseconds via the −/+
buttons, which the slats require for a
complete change in direction of their angle.
The time for an individual step is
fixed at 200 ms and cannot be
changed.
[8] Behaviour during faults
Display of information only. No
settings are possible.
[8] Setting the motor pause time in milliseconds
via the -/+ buttons
Please check the operating
manual of the blind motor for
specifying the correct pause time
of the motor (period between
switching the actuator and start-
up of the motor). This value is
required for the setting of the
slats.
[1] Changing the name
[2] Deleting the channel
[3] Selecting the rocker in the list view
│25