Burner Assembly - Riello RDB 3.2 BT 50/70 Installation, Use And Maintenance Instructions

Kerosene burner
Table of Contents

Advertisement

5.7

Burner assembly

CF Application
In case of CF applications, the burner shall not operate without
protection (A) of the suction inlet.
BF Application
The temperature of the incoming air must not
exceed 70 °C.
CAUTION
For correct BF application, the burner must be in-
stalled on an appropriate BF boiler.
WARNING
In case of BF applications an optional snorkel and gasket are
available replacing (A) with (B).
This item can be supplied separately.
20148107
Installation
The combustion air supply is through a flexible or rigid pipe con-
nected to the air intake.
Consequently, you must comply with the following requirements
and instructions:
A
 The combustion air intake tube must be:
 The intake-tube / burner system must not allow a loss of
for instance, the above requirements will be met if you use flues
Fig. 7
D5884
for pressure exhaust of flue gases (the condensation kind).
 Make sure the air intake tube's inlet is positioned so that it is
 The inside diameter of the hose must be at least 80 mm.
 The intake tube can be up to 6 metres in length.
WARNING
NOTE:
Burner installation must in any case comply with the flue
systems included within the boiler approved configuration.
B
WARNING
Fig. 8
D5883
14
GB
- fastened securely to the burner;
- made of a suitable material, with temperature characteris-
tics in the range - 30 °C to 80 °C;
- in compliance with all requirements of applicable regula-
tions in force in the country of destination.
3
over 2 m
/h at 0.5 mbar:
not likely to be obstructed by foreign matter and, where nec-
essary, use suitable screens.
Length is reduced if there are bends in the intake
section.
For instance, using a tube with a smooth inside
surface, you must allow for the following losses:
– for each 45° bend, tube length is reduced by
0.5 m;
– for each 90° bend, tube length is reduced by
0.8 m.
 Under no circumstances should the air's
entry in the hose intake area be obstructed.
 The hose must not be blocked in any way or
feature a shutting device (valves, membranes
etc.).

Hide quick links:

Advertisement

Table of Contents
loading