Download Print this page
Sealey AK459DX.V2 Manual

Sealey AK459DX.V2 Manual

Gravity & suction feed/air discharge oil drainer

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instruction
gloves
manual
1. safety
WarninG: ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
Familiarise yourself with the application and limitations of the oil drainer, as well as the potential hazards.
9
WarninG: disconnect the drainer from the air supply before changing accessories, servicing or performing any maintenance.
maintain the drainer in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Keep the drainer clean for best and safest performance.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
WarninG: ensure correct air pressure is maintained and not exceeded.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are
9
secure.
do not use the drainer for any purpose other than that for which it is designed.
8
do not operate the drainer if any parts are damaged or missing as this may cause failure and/or personal injury.
8
do not stand on the drainer.
8
do not adjust or tamper with the safety valve.
8
do not move the drainer by the hose, or pull the hose sharply from the air supply.
8
do not place attachments close to your face and do not point hose at other persons or animals.
8
do not allow untrained persons to operate the drainer.
8
do not operate the drainer when you are tired, under the influence of alcohol, drugs or intoxicating medication.
8
do not leave the drainer operating unattended.
8
do not direct air from the air hose at yourself or others.
8
When not in use disconnect from the air supply, vent reservoir and store in a safe, dry, childproof area.
9
dispose of waste oil in accordance with local authority regulations.
9
WarninG: do not pollute the environment by allowing uncontrolled discharge of waste oil.
2.
introduction
i
Steel fabricated 90ltr reservoir and telescopic steel drain pan fitted with filter grid. Venturi suction pump powers oil dipstick probes
and includes a set of quick release probes. Gravity or suction feed reservoir with air discharge. Fitted with oil level indicator tube.
Supplied with mercedes adaptor.
3.
specification
i
Model no: ........................................................aK459dX.v2
Capacity: ........................................................................ 90ltr
minimum Height to Pan: .......................................... 1300mm
maximum Height to Pan: ......................................... 1750mm
Gravity Feed: .................................................................. Yes
Suction Feed: .................................................................. Yes
Gravity discharge: ........................................................... no
Air discharge: ................................................................. Yes
Pump discharge ............................................................... no
4. air supply
4.1.
Recommended hook up is shown in fig.1.
4.2.
Ensure the air valve is in the "Off" position before connecting to the air supply.
4.3.
You will require an air pressure of 7 bar.
WarninG: ensure the air supply is clean and does not exceed pressures
specified in these Instructions. Too high an air pressure and/or unclean air will
shorten the drainer life due to excessive wear, and may be dangerous.
© Jack Sealey limited
Gravity & suction feed/air discharGe
oil drainer
model no:
Wear eye
Wear protective
protection
clothing
Original Language Version
aK459dX.v2
fig.1
AK459dX.V2 Issue 2 19/11/18

Advertisement

loading

Summary of Contents for Sealey AK459DX.V2

  • Page 1 Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 6.2.5. Connect the suction hose to the probe. 6.2.6. Open valve (fig.6.1), keeping the probe dipped in oil. As soon as the sump is emptied, close valve (fig.6.1). note! It is also possible to suck hot waste oil while keeping the air connected to the device. fig.5 AK459dX.V2 Issue 2 19/11/18 Original Language Version © Jack Sealey limited...
  • Page 3 (fig.8.5) and/or air valve (fig.7.2). note! The unit storage tank has been fitted with a safety valve factory calibrated to 0.5Bar/7.25psi. note! Some cars have a built-in suction probe. In this case, check vehicle manufacturer’s data to determine the correct suction probe to be used (fig.9). AK459dX.V2 Issue 2 19/11/18 Original Language Version © Jack Sealey limited...
  • Page 4 Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. sealey Group, Kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...