Download Print this page

Delta DOP-100 Series Instruction Sheet page 2

Hide thumbs Also See for DOP-100 Series:

Advertisement

(4) Mounting dimensions
DOP-112MX / DOP-112WX
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F)
DOP-115MX / DOP-115WX
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F)
(5) Installation and wiring
Precautions:
Incorrect installation may result in malfunction
To ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the
adjacent objects or walls.
This product should be used on a case / platform which conforms to enclosure Type 4X standard
(for indoor use only).
The maximum panel thickness for mounting must be no greater than 5 mm.
Installation steps:
Step 1:
Put the waterproof gasket into the HMI and then
insert the HMI into the panel cutout.
Unit: mm (inch)
Step 3:
Tighten the screws with the torque less than
0.5 N-M / 0.7 N-M to avoid damage to the plastic
case.
Torque for DOP-112MX / 112WX / 115MX /
115WX: 6.17 lb-inch (0.7 N-M)
Wiring:
Type
Wire gauge (AWG)
Solid
24
Stranded
24
Please refer to the following diagram when wiring the power connector. The temperature
rating of the cable must be greater than 75°C (167°F).
Step 2:
Place the fasteners into the slots and tighten
the screws until reaching the panel cutouts.
Step 4:
For heat dissipation, please keep a minimum
clearance of 60 mm on the rear of the HMI.
Stripped length
Torque
12
7
8 mm
5 kg-cm (4.3 lb-in)
12
7
8 mm
5 kg-cm (4.3 lb-in)
(6) Hardware specifications
DOP-112MX
Model
DOP-112WX
Panel type
12.1" TFT LCD (24-bit color)
Resolution
1024 x 768 pixels
Backlight
LED Back Light (half-life under room temperature 25°C > 50,000 hours)
Display range
245.76 mm x 184.32 mm
Brightness
500 cd / m² (Typ.)
CPU
Dual 1GHz
Flash ROM
RAM
DDR3 1000MHz 1GB
Touchscreen
4-wire resistive touchscreen > 10,000,000 operated
Buzzer
Multi-Tone Frequency (2K – 4K Hz) / 85 dB
100M bps x 1
Network interface
1000M bps x 1
USB
1 Mini USB Ver 2.0; 1 USB Host Ver 2.0
SD
SD x 1
COM1
RS-232 (supporting flow control) / RS485
COM2
RS-422 / RS485
COM3
RS-232 (supporting flow control) / RS-485
COM4
RS-422 / RS485
Auxiliary function key
Calendar
Built-in
Cooling method
Natural cooling
CE / UL
Approvals
(please use shielding network cable and magnetic ring with the filter of
300 ohm / 100 MHz)
Panel waterproof level
IP65 / NEMA4 / Type 4X for indoor use only
DC +24V (-15% to +15%) (please use an isolated power supply)
Operation voltage
*2
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)
Leakage current
500 V
for 1 minute (between DC24V terminal and FG terminal)
AC
Power consumption
*2
16.08 W (Max)
*3
Backup battery
3V lithium battery CR2032 × 1
About 3 years or more at 25°C
Backup battery life
(subject to operating temperature and condition)
Operating temperature
0°C to 50°C (32°F to 122°F)
Storage temperature
-20°C to +60°C (-4°F to 140°F)
10% to 90% RH [0°C - 40°C], 10% to 55% RH [41°C - 50°C];
Operating environment
pollution degree: 2
Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with amplitude
Vibration resistance
3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G
Conforms to IEC60068-2-27:
Shock resistance
11 ms, 15 G Peak, in X, Y, Z directions each for 6 times
Dimension
317.4 x 246.4 x 52.7
(W) x (H) x (D) mm
Mounting dimension
302.7 x 228.7
(W) x (H) mm
Weight
Approx. 2,110 g
Note:
1. The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the
maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the
room temperature of 25°C with ambient humidity.
2. The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
3. The HMI power consumption is the power consumed when the HMI is not connecting with other
peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power
supply is 1.5 to 2 times of the specified power consumption.
4. Isolated power supply is recommended.
5. For the DOPSoft programming software of the DOP-100 series and the user manual, you can
download them at http://www.delta.com.tw/ia.
6. DOP-100 series can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
DOP-115MX
DOP-115WX
15.1" TFT LCD (24-bit color)
*1
304.1 mm x 228.1 mm
450 cd / m² (Typ.)
8GB
*2
*2
*2
N/A
21.12 W (Max)
*3
387.7 x 295.7 x 63.5
372.4 x 283.7
Approx. 3,200 g

Advertisement

loading

This manual is also suitable for:

Dop-112mxDop-112wxDop-115mxDop-115wx