Delta DOP-100 Series Instruction Sheet

Delta DOP-100 Series Instruction Sheet

High color/wide screen
Hide thumbs Also See for DOP-100 Series:

Advertisement

Available languages
  • EN

Available languages

-
DOP
107EV
High color‧Wide screen‧User-friendly
Delta Electronics, Inc.
DOP-107CV
No.18, Xinglong Rd., Taoyuan City
33068, Taiwan
Instruction Sheet

(1) General precautions

Thank you for purchasing this product. This instruction sheet provides information about the DOP-100
series HMI. Before using this product, please read through this instruction sheet carefully to ensure the
correct use of the product. Please keep this sheet handy for quick reference whenever needed. Before
finishing reading this sheet, please follow the instructions below:
Install the product in an indoor location, which is free of vapor, corrosive and inflammable gas and
liquids.
Please refer to the wiring diagram when connecting the wires.
Ensure your HMI is correctly grounded. The grounding method must comply with the national
electrical standard (please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble the HMI or change the wiring when power is on.
Do not touch the power supply when power is on, or it may cause electric shock.
When the HMI displays a low power notification and requires a battery change, please contact
your local distributor or Delta Customer Service Center for the replacement. Do not change the
batteries by yourself.
This product can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
Cleaning method: please use a dry cloth to clean the product.
This product must be used at an altitude below 2,000 m.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
For repair and maintenance, please contact Delta Electronics, Inc. Address: No.18, Xinglong Rd.,
Taoyuan City, Taiwan. TEL: +886-3-3626301.
If you have any inquiry during operation, please contact our local distributors or Delta sales
representatives. The content of this instruction sheet may be revised without prior notice. Please consult
our distributors or download the latest version at Delta's website (http://www.delta.com.tw/ia).

(2) Communication port pin assignment

DOP-107CV / DOP-107EV COM1
COM Port
Pin
1
2
3
4
5
6
7
8
9
DOP-107CV / DOP-107EV COM2
MODE1
COM Port
Pin
COM2
COM3
COM2
RS-232
RS-485
RS-485
1
-
-
D+
2
RXD
-
3
TXD
-
4
-
D+
5
GND
6
-
-
7
RTS
-
8
CTS
-
9
-
D-
Note: mark "-" means connection is not required.

(3) Description of each part

DOP-107CV / DOP-107EV (front view)
DOP-107CV / DOP-107EV (rear view)
MODE1
RS-232
-
RXD
(4)
Mounting dimensions
TXD
-
DOP-107CV / DOP-107EV
GND
-
RTS
CTS
-
MODE2
MODE3
COM3
COM2
COM3
RS-485
RS-232
RS-422
-
-
TXD+
-
-
RXD
-
-
-
TXD
-
-
D+
-
RXD+
GND
GND
D-
-
-
TXD-
-
-
RTS
-
-
-
CTS
-
-
D-
-
RXD-
A
Operation / display area
Power input terminal
A
B
COM2/COM3
(24AWG wire min.)
C
COM1
D
USB Host
Network port (LAN)
E
F
USB Slave
Only for DOP-107EV
Operation temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F)

(5) Installation and wiring

Precautions:
Incorrect installation may result in malfunction.
To ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the
adjacent objects or walls.
This product should be used on a case / platform which conforms to enclosure Type 4X standard
(for indoor use only).
The maximum panel thickness for mounting must be no greater than 5 mm.
Copper conductor only.
Installation steps:
Step 1:
Put the waterproof gasket into the HMI and
then insert the HMI into the panel cutout.
Step 3:
Tighten the screws with the torque less than
0.5 N-M / 0.7 N-M to avoid damage to the
plastic case.
Torque for DOP-107CV / DOP-107EV:
6.17 lb-inch (0.7 N-M)
Wiring:
Type
Wire gauge (AWG)
Solid
24 – 12
Stranded
24 – 12
Please refer to the following diagram when wiring the power connector. The temperature
rating of the cable must be greater than 75°C (167°F).
Unit: mm (inch)
Step 2:
Place the fasteners into the slots and tighten
the screws until reaching the panel cutouts.
Step 4:
For heat dissipation, please keep a minimum
clearance of 60 mm on the rear of the HMI.
Stripped length
Torque
7 – 8 mm
5 kg-cm (4.3 lb-in)
7 – 8 mm
5 kg-cm (4.3 lb-in)

Advertisement

Table of Contents
loading

Summary of Contents for Delta DOP-100 Series

  • Page 1 When the HMI displays a low power notification and requires a battery change, please contact Step 3: Step 4: your local distributor or Delta Customer Service Center for the replacement. Do not change the Tighten the screws with the torque less than For heat dissipation, please keep a minimum batteries by yourself.
  • Page 2 1.5 to 2 times of the specified power consumption. 4. Isolated power supply is recommended. 5. For the DOPSoft programming software of the DOP-100 series and the user manual, you can download them at http://www.delta.com.tw/ia. 6. DOP-100 series can be used with other industrial automation equipment. Please read through this...
  • Page 3 Ürünle ilgili sorularınız için firmamız ile kontak kurabilirsiniz. Ürünün kullanımı ile ilgili sorularınız için teknik servisimizle kontak kurabilirsiniz. Bu bilgi dokümanının içeriği herhangi bir bildirime gerek duyulmadan değiştirilebilir. Dokümanın son versiyonunu internetten indirebilirsiniz. http://www.delta.com.tw/ia. (2) Haberleşme Pinleri Güç Giriş Soketi...
  • Page 4 İzoleli güç kaynağı kullanılması tavsiye edilir. DOP-100 serisi ürünlerin program editörü olan DOPSoft programı ve kullanıcı manuel’i web sayfamızdan indirilebilirsiniz. http://www.delta.com.tw/ia. DOP-100 serisi endüstriyel otomasyon donanımı olarak kullanılabilir. Tehlikeleri önlemek için bu bilgi dokümanını dikkatlice okuyun ve belirtilen direktiflere göre kurulumu gerçekleştirin.
  • Page 5 DOP-107CV / DOP-107EV (正面) 安裝方向必須依規定,否則會造成故障。  為了使冷卻循環效果良好,安裝人機介面時,其上下左右與相鄰的物品和擋板(牆)必須保持足夠的空  間,否則會造成散熱不良。 -107EV 使用於 Type 4X 室內用等級之外殼平面。  高彩‧寬螢幕‧友善人機介面 安裝面板最大板厚請勿超過 5 mm。  Delta Electronics Inc, DOP-107CV 請用銅製導線。  No.18, Xinglong Rd., Taoyuan City 33068, Taiwan 安裝示意圖: 安裝說明 步驟⼀: 步驟二: 請確實將防水墊圈裝入,然後再安裝人機介面。 請確實將固定片螺絲組裝入內,然後下方鉤住 (1) ⼀般注意事項...
  • Page 6 196.9 x 142.9 (W) x (H) mm 重量 約 970 g 註: 1. 背光模組半衰期的定義:最大驅動電流下,背光亮度衰退到最大亮度的⼀半時,即為半衰期。所標示之 壽命時間為 25 C 常溫常濕工作環境下之預估值。 2. 隔離電路耐受規格:可承受 1 分鐘 1500 V 高壓突波。 3. 消耗功率為無外接週邊設備時,人機本體所消耗的功率。建議選用的電源供應器容量為標示消耗功率之 1.5 ~ 2 倍,以確保人機工作正常。 4. 建議使用隔離式電源供應器。 5. DOP-100 系列編輯軟體 DOPSoft 系列及其使用操作手冊,可由台達網站下載取得,網址為 http://www.delta.com.tw/ia。 6. DOP-100 系列適用於工業自動化設備,請詳細閱讀此說明,並依指示安裝避免產生危險。...
  • Page 7 安装方向必须依规定,否则会造成故障。  为了使冷却循环效果良好, 安装人机界面时, 其上下左右与相邻的物品和挡板(墙)必须保持足够的空间, 否则会造成散热不良。  使用于 Type 4X 室内用等级的外壳平面。  安装面板最大板厚请勿超过 5 mm。 DOP-107EV 高彩‧宽屏幕‧友好人机界面 请用铜制导线。  Delta Electronics Inc, 安装示意图: No.18, Xinglong Rd., Taoyuan City DOP-107CV 步骤一: 步骤二: 33068, Taiwan 请确实将防水垫圈装入,然后再安装人机界面。 请确实将固定片螺丝组装入内,然后下方钩住 安装说明 前盖螺丝头顶住控制箱内侧。 (1) 一般注意事项 感谢您使用本产品,本人机界面安装说明书提供 DOP-100 系列人机界面的相关信息。在使用之前,请您仔...
  • Page 8 196.9 x 142.9 (W) x (H) mm 重量 约 970 g 注: 1. 背光模块半衰期的定义:最大驱动电流下,背光亮度衰退到最大亮度的一半时,即为半衰期。所标示的 寿命时间为 25 C 常温常湿工作环境下的预估值。 2. 隔离电路耐受规格:可承受 1 分钟 1500 V 高压突波。 3. 消耗功率为无外接周边设备时,人机本体所消耗的功率。建议选用的电源供应器容量为标示消耗功率的 1.5 ~ 2 倍,以确保人机工作正常。 4. 建议使用隔离式电源供应器。 5. DOP-100 系列编辑软体 DOPSoft 系列及其使用操作手册,可由台达网站下载取得,网址为 http://www.delta.com.tw/ia。 6. DOP-100 系列适用于工业自动化设备,请仔细阅读此说明,并依指示安装避免产生危险。...

This manual is also suitable for:

Dop-107cvDop-107ev

Table of Contents