Reset Authentication Table Button (AZedit Only)

The Reset Authentication Table button (see Figure 8 on page 20) is used to reset the authentication to the RVON+ card. By
clicking this button, the authentication table for IPedit is reset to the two default user profiles and passwords. Use this function
when the password for IPedit cannot be remembered.
The default user profiles are:
telex – password
admin – password
To reset the authentication table to its default profiles, do the following:
From the System menu, select Miscellaneous|RVON Configuration.
1.
The RVON Configuration window appears.
From the Slot drop down menu, select the slot of the RVON+ card.
2.
Click the Reset Authentication Table button.
3.
A verification message appears.

Enter Boot loader Mode

The RVON+ card is shipped with current firmware pre-installed from the factory. The firmware includes a boot loader, which
is used if the application program becomes corrupt (for example, if the card is reset while it is reprogramming the flash).
To force the card into boot loader mode, do the following:
On the RVON+ front card, press and hold the two front card buttons.
1.
Press the Reset button.
2.
The card starts the reset process.
Once the green LEDs start tracking back and forth, release the 1 and 2 buttons.
3.
The card is in boot loader mode.
NOTE:
To verify the RVON+ card is in boot loader mode, open the AZedit I/O Card Version dialog (Status | Software
Versions | I/O Cards).