Materials List; Tools List; Basic Package Contains - DataRemote Pots In a Box CDS-9090 User Manual

Lte voip dual band wi-fi router
Hide thumbs Also See for Pots In a Box CDS-9090:
Table of Contents

Advertisement

SCOPE OF WORK. (Continued)
Mount the biscuit (RJ-11 Surface mount) jacks close to the DataRemote CDS-9090 device
that will connect with the remote device.
Connect existing devices to newly installed RJ11 biscuit jacks.
Ensure no "Foreign Voltage" is present by measuring the voltage at the tip and ring
terminals on the new biscuit jacks connected to the devices. Voltage should read: "zero"
volts DC (direct current)
voltage is present, proceed to next step
Connect the DataRemote CDS-9090 device FXS 1-8 (if applicable) jacks to existing devices.
If Call Box or Voice line, test by making inbound/outbound calls.
If Call Box also test 'Gate/Door Entry" tone (DTMF / 'Press 9") and programming calls
inbound to the device.
programming test calls as needed.
If Fire Alarm Panel, test that Fire Alarm Panels primary & secondary lines accordingly, calling
out through the DataRemote CDS-9090 device. If RJ-31 style jack is used, verify that tip/ring
connections are on pins 4 & 5 of jack.
If FAX, test by sending/receiving FAX using customer equipment.

MATERIALS LIST.

PROVIDED BY DATAREMOTE:
Basic Package Contains (Refer to "What comes in the Box" section)
One (1) DataRemote CDS-9090 device.
One (1) 100-240VAC, 50/60Hz, 1.0A to 15.0VDC, 2.0A power adapter.
One (1) AC power cord.
One (1) Ethernet cable RJ-45.
Two (2) Phone cable RJ11.
Two (2) LTE antennas (SMA-M connectors)
Two (2) Wi-Fi antennas (SMA-M-RP connectors)
One (1) Mounting bracket.
TOOLS LIST FOR TECH:
Sufficient quantity of dual RJ-45 port surface mount boxes (aka biscuit jack)
Sufficient quantity of RJ11 or RJ-45 keystone plugs
CAT5E cable – minimum 150'
Power strip (this may not be used, it is in case there are not enough outlets in the room)
Zip Ties / Velcro for wire management
Extra RJ-11 cable and RJ-11 male adapters, in the event additional or longer runs are
required.
IMPORTANT! IF foreign voltage is present, locate and disable it. IF no foreign
Request client or call vendor technical support to facilitate
Revision No. 004 April 2020
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for DataRemote Pots In a Box CDS-9090

This manual is also suitable for:

Cds-9090

Table of Contents