Huawei UA5000 Commissioning Manual page 83

Universal access unit product
Hide thumbs Also See for UA5000:
Table of Contents

Advertisement

UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI
until no packets are lost in a short period (you can ping the peer device on the UA5000 to check
the packet loss). Note that the adjusting process should be performed stably and slowly.
Step 5 Unplug the patch cord of the detected port, connect the unplugged patch cord to the optical power
meter, and record the input optical power of this point through the optical power meter.
Step 6 If the detected optical power does not meet the technical requirement (for detailed technical
specifications, see the following table), check whether the detecting wavelength set for the
optical power meter is consistent with the working wavelength input by the detected power. In
addition, check whether the optical port is connected tightly.
Step 7 If the detected value meets the technical standard, resume the fiber connection of the detected
port.
----End
Result
The input optical power of the detected port meets the technical requirements.
Technical specifications of the optical fiber port:
1000Base-Lx
Table 3-30 Technical specifications of the 1000base-Lx port
Parameter
Transmission rate
Interface type
Interface mode
Transmission distance (km)
Central wavelength (nm)
Mean transmit power (dBm)
Extinction ratio (dB)
Receiver sensitivity (dBm)
Receiver overload power (dBm)
Standards compliance
1000Base-Zx
Table 3-31 Technical specifications of the 1000Base-Zx port
Parameter
Transmission rate
Issue 04 (2012-06-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Specification
1000 Mbit/s
LC
Single mode
10
1310
-11 to -3
8.2
< -19
-3
IEEE 802.3z
Specification
1000 Mbit/s
3 Stand-Alone Commissioning
75