STARTING SYSTEM
Starter Solenoid
TESTING / REPLACEMENT
Pinion clearance must be checked after reassembly of starter motor.
1. Disconnect brush lead from solenoid motor and insulate it carefully.
2. Connect 12 volt battery positive (+) lead to battery terminal and negative (–) lead to
frame.
3. Momentarily touch a jumper lead from battery terminal to switch terminal. This shifts pin-
ion into cranking position where it will remain until battery is disconnected.
4. Push pinion back toward commutator end to eliminate slack.
5. Measure distance between pinion and pinion retainer.