Following the all reset operation, the NX Unit settings are initialized as noted below.
Home Time:
Washington, D.C.
JAN/1/1996 MON
12:00 AM
12-hour format
World Time:
New York
Daily Alarm:
12:00 PM
Sound:
Schedule alarm, Reminder alarm and To Do alarm — ON
Daily alarm — OFF
Key input tone — ON
Input mode:
Overwrite

TO SAVE THE DATA TO ANOTHER UNIT

NX-4000/6000 can transfer customer's data to another NX-4000/6000 with memory protection only when
replacing the LCD or the outer case.
How to transfer the data
1) Make sure that the power of both units is switched off.
2) Remove the covers from the data communications jacks on the two NX units.
3) Connect the two units using the SB-62 cable as shown in the figure below.
4) Turn the power switch of slave units on.
5) Reset the slave unit.
6) The slave unit must be set the date of Feb. 3rd, 1901 into the memory under the calculator mode.
Operation : ON
If you don't set the date, the "PASSWORD" isn't transferred to the slave unit.
7) Check the hardware parameters, and if the both units have another condition, reset as follows;
Operation : MENU
SB-62 cable
AC
1
DATE
FUNC
DATA COM.
— 6 —
2
DATE
3
SET UP PAR.
NONE
//////////// SET UP PAR. ////////////
PARITY
EVEN ODD
BIT LENGT
BPS
DATE
M+
7
9600
OK
NONE
7
8
4800 /
9600