8) Set up the slave unit.
Operation : MENU
9) Set up the customer's unit.
• Turn the power switch off.
• Press the RESET button with a thin, pointed object while shorting the following pad.
BOTTOM VIEW
Note: Be careful not to reset the customer's unit. If "DIGITIZER" is displayed, turn the power switch off
immediately, and try again.
10) Start the data communication (slave unit).
Operation : OK
If you can not succeed to transfer the data, press ESC key on both unit and try to transfer the data again
according to the above procedure.
FUNC
DATA COM.
Enlarge
Short the pad
— 7 —
RECEIVE
RECEIVE OK!
DATA
TO STOP
PRESS [ ESC ]
OK
SEND ALL DATA ?
OK
RECEIVING
RECEIVE OK!
ITEMS 00001
DATA
TO STOP
PRESS [ ESC ]
OK
ESC
ESC
ESC