FAAC H4 Installation And Use Instructions Manual

Alarm control unit with siren and telephone transmitter

Advertisement

Quick Links

H4 Alarm Control Unit
and telephone transmitter
with siren
Installation and use
instructions
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal

Advertisement

Table of Contents
loading

Summary of Contents for FAAC H4

  • Page 1 H4 Alarm Control Unit with siren and telephone transmitter Installation and use instructions 2 secs. Alarm ON / Alarm OFF Maintenance Program mode Alarm memory-stored / In progress System sabotage alarm Discharged batteries Peripheral units fault / Telephone line fault...
  • Page 3: Table Of Contents

    Presentation of H4 alarm control unit ........
  • Page 4: Presentation

    PRESENTATION Maximum capacity of the elements supported by the PRESENTATION OF THE SYSTEM system: - various detectors 40 max This system's devices communicate on two different - remote-controls 14 max frequency bands: the messages emitted between - emergency call panic buttons 4 max the control unit, the detectors, and the warning - control keypads...
  • Page 5 THE AREAS (AREA 1 - AREA 2 - AREA 3 - AREA 4) The areas can be selected from a control keypad (Area from 1 to 4). The configuration of the areas, i.e. the enablement of the detectors, is done by a keypad and by the detectors to be integrated in each area.
  • Page 6: Presentation Of H4 Alarm Control Unit

    PRESENTATION OF H4 ALARM CONTROL UNIT The siren control unit is the main part of the alarm The transmission control unit manages intrusion system. It analyses the detectors' messages, detections and domestic risks. transmits alarm toward siren A powerful 102 dB siren is integrated in it.
  • Page 7: Indicator Lights Status

    INDICATOR LIGHTS STATUS Fault indicator Operation indicator lights light (yellow) flash 0.1s / 1s MAINTENANCE PROGRAM mode lighted on steady beam lighted on steady beam ADD DEVICES menu status flashes 0.5s / 0.5s flashes 0.5s / 0.5s AREA CREATION menu status 2 secs.
  • Page 8: Preparation - Positioning

    INSTALLATION PREPARATION - POSITIONING Choice of location Before installing, you must adequately select the place where the control unit will be located (for the other devices, consult the relevant instructions). Radio wave propagation rate: plaster, wood, reinforced Installation precautions plasterboard concrete from 90 to 100% from 10 to 70%...
  • Page 9: Securing

    SECURING 2 secs. Alarm ON / Alarm OFF Maintenance Program mode Alarm memory-stored / In progress - Open the battery compartment with the supplied System sabotage alarm Discharged batteries key. Peripheral units fault / Telephone line fault Passage open signal - Loosen the two securing screws and remove the SUPTEST front cover.
  • Page 10: Electrical Connections

    ELECTRICAL CONNECTIONS Putting into operation Discharged batteries Peripheral units fault / Telephone line fault Passage open signal - Fit the batteries, respecting the indicated polarity. TEST The yellow indicator light “flashes” indicating that the control unit is in Maintenance Program mode and is ready to memory-store the control keypad as the first element.
  • Page 11 Wiring the outputs The control unit supplies status and alarm information. Cable route Status: Closed contact: alarm system enabled. Open contact: alarm system disabled. Alarm: output of alarm in progress (open collector). The output, which is normally floating, is earth connected when the alarm is tripped.
  • Page 12: Programming

    PROGRAMMING GO TO ADD DEVICES MODE Learning of a MASTER remote-control When purchased, the control unit is not The MASTER remote-control must be the first programmed. remote-control to be programmed. In fact, the Master remote-control is essential for To ensure that the control unit recognises the adding any other remote-control.
  • Page 13: Registering Devices

    REGISTERING DEVICES Step 2: put in ADD DEVICES mode. - press the ON key of the slave remote-control for Note: the control unit must be in MAINTENANCE about one second, PROGRAM mode and in ADD DEVICES menu - press the ON key again (for about 1 second); you (yellow indicator light on steady beam).
  • Page 14: Deleting Devices

    DELETING DEVICES Note: the control unit must be in MAINTENANCE PROGRAM mode and in ADD DEVICES menu. This procedure makes it possible to delete the identity of the devices from the control unit memory: To eliminate all the devices except the outdoor siren - Press for more than 5 seconds the yellow DELETE (EFF) push-button of the control unit.
  • Page 15: Areas

    AREAS The transmission control unit can be used to obtain Eliminating devices from an area selective protection of the rooms, indicated by the term “AREA”. Only the intrusion detector can be In case of an error, you can eliminate devices, assigned to an AREA.
  • Page 16: Customising The System

    CUSTOMISING THE SYSTEM ACCESS TELEPHONE TRANSMITTER The control unit must be in MAINTENANCE PROGRAM mode (See Alarm Control Unit Instructions). Method 1 Method 1: Type in the number of the system from an From a different telephone line - mobile or fixed - external line type in the number of the system.
  • Page 17: Modifying The System Parameters

    MODIFYING THE SYSTEM PARAMETERS MODIFYING THE TELEPHONE NUMBERS Call Access code Customising - access to the customising menu, - to modify the telephone numbers to be called, press push-button 1 of the telephone. The transmitter asks you to type in the position of the telephone number to be modified.
  • Page 18 HOW TO MODIFY THE VOICE MESSAGE - access the customising menu, - press push-button 2 of the telephone. Call Access code Customising The transmitter repeats the current voice message and then invites you to speak after an acoustic signal, to record the new message. - wait for the beep, and then speak, Select the function - confirm by pressing...
  • Page 19: Control Unit Internal Functions

    CONTROL UNIT INTERNAL FUNCTIONS 2 secs. Alarm ON / Alarm OFF Maintenance Program mode Alarm memory-stored / In progress System sabotage alarm Discharged batteries Peripheral units fault / Telephone line fault Passage open signal CONTROL UNIT INTERNAL SIREN TEST In case of an alarm due to intrusion, the control unit's internal siren is enabled.
  • Page 20: System Test

    SYSTEM TEST Test of control and information keypad - Press the key. The display shows “-- -- -- --”. The control unit must be in MAINTENANCE INFO INFO - Press the key. PROGRAM mode The control unit and keypad emit a beep. We advise you to run the test so that you can verify - after installation - if all the elements of your alarm system are operating correctly.
  • Page 21 Test for registering the first telephone number Press for more than 30 seconds the transmission control unit's TEST push-button. It will call the first registered number. Test for checking if the transmission control unit engages the line. Make a telephone call to a friend or neighbour, with the phone connected to the control unit's line.
  • Page 22: Use

    STATUS DIAGRAM (use with radio control) Press the MAINTENANCE Press ADD DEVICES ON key PROGRAM for a long time Open the battery compartment (you have 1 minute to do this) Close the battery compartment Press 1 + 2 and then press the OFF Key for a long time (Master only) ALARM...
  • Page 23: System Management In Local Mode

    SYSTEM MANAGEMENT IN LOCAL MODE Alarm cycles / Trip the detection When the alarm is tripped, the acoustic signal is enabled for 90 seconds. After all the elements have been installed and It can be stopped by the OFF function of a control programmed correctly, you can put your system into device.
  • Page 24: Management By Telephone

    MANAGEMENT BY TELEPHONE READ THIS BEFORE ANY USE Wait for the end of the phrases before pressing the keys, when carrying out the different configurations and consultation of the system. The transmitter will automatically disconnect itself if no pressure is exerted for 90 seconds. To return at any time to the main menu, starting off from any function, press key of the telephone.
  • Page 25 To listen to the protected rooms - access the main menu - press push-button 2 of the telephone At this point, the transmission control unit allows the user to listen to what is happening in the rooms, or to change over to the function “Speak in the protected rooms”...
  • Page 26 Enable or disable the alarm system - access the main menu, - press push-button 1 of the telephone The transmitter shows the main menu, indicating the system's new status (ON or OFF). - select another function or hang up. Call Access code Access the customising menu The control unit must be in MAINTENANCE...
  • Page 27 How to manage an alarm Following an alarm, the telephone transmitter calls a number according to the preset calls cycle. - the telephone rings, lift the handset. - press key Lift up the handset The transmitter announces the welcome message, and then communicates the alarm, indicating the time, type (e.g.
  • Page 28: Indicator Lights

    INDICATOR LIGHTS ADD DEVICES Menu 2 secs. MAINTENANCE PROGRAM Alarm ON / Alarm OFF Maintenance Program mode mode Alarm memory-stored / In progress Detector Alarm memory-stored / In progress Sabotage memory-stored Remote-control System sabotage alarm Sabotage in progress except control unit Control and information keypad Discharged batteries...
  • Page 29 DELETING THE EVENTS YELLOW OPERATION INDICATOR LIGHT When you come back, and change over to disabled - Under normal operation conditions, the indicator alarm mode, the control unit signals (with beeps) if light is OFF. any alarm events have occurred during your - When the alarm is enabled or disabled, the absence.
  • Page 30: How An Alarm Takes Place

    HOW AN ALARM TAKES PLACE OPERATION OF TELEPHONE CALLS DURING AN ALARM Events sending The telephone transmitter element makes calls on the switched telephone network (STN), according to the following principle: 2 secs. Alarm ON / Alarm OFF Maintenance Program mode Alarm memory-stored / In progress System sabotage alarm Discharged batteries...
  • Page 31 Remote access to telephone transmitter There are two simple ways of calling the transmitter: - just type in the number of the line to which you are connected. It will answer after 10 ring tones. This time interval can be adjusted, by typing in the # 81 xx command on the telephone in the main menu.
  • Page 32: Enclosures

    ENCLOSURES TECHNICAL SPECIFICATIONS - Power supply: four 1.5 Volt alkaline batteries - Radio range: type LR20 (or D) in free field: from 200 to 300 m, according to environment - Time range: 2.5 years under normal use indoors: according to environment conditions - Enclosure: ABS - Functions:...
  • Page 33: Customised Configuration Panel

    CUSTOMISED CONFIGURATION SUMMARY To facilitate putting the system into operation, we advise you to do the following: - write the configuration of your system in the following table (type of detector, location, configuration , etc.), - identify every detector (with numbers). Remember that the control and information keypad enables you to assign names, which are already present in the system's memory.
  • Page 34: Glossary

    GLOSSARY Alarm - Dissuasion acoustic signal, emitted by a siren, when intrusion occurs - Status of system when an intrusion occurs. - Common name for an alarm system. Area A set of devices which operate at the same time, associated with partial enablement of the system.
  • Page 35: Ce Declaration

    CE DECLARATION R&TTE DECLARATION OF CONFORMITY Effective use of the radioelectric spectrum: Name: H4 Alarm Control unit with siren and telephone transmitter EN 300-220_3 V1.1.1(September 2000) EN 300-220_1 V1.3.1(September 2000) Chapter 9.3.3 Distributor: FAAC S.p.A. Via Benini, 1 - 40069 Zola Predosa - Bologna (Italy)
  • Page 36 The descriptions and illustrations in this manual are not binding. While leaving the essential characteristics of the equipment unaltered, FAAC reserves the right, at any time and without having to update this publication, to make the modifications which it considers convenient for technical improvements or for any other construction or...

Table of Contents