Method For Measuring Bucket Foot Angle - Komatsu PC360LCi-11 Operation & Maintenance Manual

Hydraulic excavator
Table of Contents

Advertisement

SETTING
Tap the inside of the white frame of dimension value to be input
again, and then the numeric keypad pops up. Input the numeric
value with it.
Measure the length dimension to mm unit, and angle to 0.1 °
unit.
You can input the numeric value within the range shown below.
Numeric value (1)
Min: 0.00001 m to Max: 19.99999 m
Numeric value (2)
Min: 0.00001 m to Max: 19.99999 m
Numeric value (3)
Min: 0.0001 m to Max: 5.9999 m
Numeric value (4)
Min: 0.0001 m to Max: 2.9999 m
Angle (5)
Min: 0.01 ° to Max: 179.99 °
Numeric value (6)
Min: 0.0001 m to Max: 5.9999 m
Check the input numeric value. If there is no problem, tap "Next" button.
If any numeric value or angle column is empty, even if "Next" button is pressed, it is invalid.

METHOD FOR MEASURING BUCKET FOOT ANGLE

1.
Set the bucket foot pin (1) and the bucket link pin (2) hori-
zontal by using a level or a laser level.
(A): When the quick coupler is not installed
(B): When the quick coupler is installed
2.
Tap the "Bucket Angle" button.
A tick is put in the check box of "Bucket Angle Read", and
work equipment angle at that posture is saved.
3.
Tap the "Next" button.
CONTROL BOX
Level the bucket and link pivot and then press
"Bucket Angle".
Bucket Angle Read
7-159