Use the following procedure to install a CAB-ATM-DS3/E3 cable and EMI filter clip:
Attach the CAB-ATM-DS3/E3 cable to the transmit (XMTR) and receive (RCVR) ports
Step 1
on the E3 PLIM, as shown in Figure 21A.
One portion of the cable has a white insulator on both ends to ensure that the
receive-to-transmit and transmit-to-receive relationship is maintained between the E3
PLIM and your ATM switch. The white banded portion of the cable should attach
between the receive and transmit or transmit and receive ports of the E3 PLIM and your
ATM switch, respectively.
Hold the EMI filter clip as shown in Figure 21B.
Step 2
Attach the EMI filter clip to the receive cable, as shown in Figure 21C.
Step 3
Make certain the EMI filter clip makes mechanical contact with the metal sleeve on the cable
Note
connector and the metal sleeve on the E3 PLIM connector.
Step 4
To ensure that the clip is not pulled off when adjacent interface processors are removed,
position the clip parallel to the orientation of the AIP, as shown in Figure 21C and D.
Asynchronous Transfer Mode Interface Processor (AIP) Installation and Configuration