Installation
1. Connect the power cord and plug power supply into a 115 volt / 60 Hz receptacle.
Note: Do not plug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off
Electronic Connections
P = Power Supply
B = Powered in Backwash Step Only
(Not Used)
S = Powered for Entire Regen Cycle
(Connection used for Ozone
Model Relay only. Not used on
non Ozone model)
IMPORTANT NOTE: Tank should be filled with water and media must have been soaking for at least 1 hour before initial
pressurization.
1. After all plumbing and drain line connections have been made, turn main water supply back on and check for leaks.
2. Ensure that the bypass valve is in the BYPASS position, and then cycle the control valve to RAPID RINSE. Once the
rapid rinse step is reached, slowly open the bypass valve to the service position, allowing water to flow down through
mineral tank and out the drain line. Let it continue to run for the entire rapid rinse step (5 minutes). There may be
colored water or media fines during this initial flow.
3. Once the rapid rinse ends, leave the system in service, and open a cold, treated water tap. Let water run for several
minutes to allow air and any media fines to be released from the lines. Once air is evacuated and water runs clear,
close the tap.
Note: Any time media (other than very fine mineral on initial startup) is apparent in the service lines, it usually indicates
one of the following problems:
A. The unit is plumbed in backward allowing the media to be carried in the service line.
B. The distributor tube inside the tank is not seated inside the valve or is damaged.
4. No further regeneration should be necessary at this time. If left at the default settings, the filter will automatically initiate
an air replenish cycle each night and will backwash every 3 days. Changing the backwash frequency to anything
other than 3 days can cause the system to not operate of function properly. Do not change unless you consult your
water treatment professional first about this setting.
6
- Electrical Connection -
P
- System Start Up Procedure-
Genesis 2 Bypass - Shown
B
S