Note: Depending upon system pressure and other factors, it is possible to observe flow to drain in the rest cycle.
-When the valve is between positions, the display will flash the number of the step it is moving towards.
-The default time at which regeneration will occur is 12:00 a.m.
The motor's run direction during a particular regeneration cycle step is indicated by the rotation direction of the
last 2 digit displays.
5 -
Example:
Master Programming Mode
To enter Master Programming Mode, press and hold both buttons for 5 seconds.
Note: All Master Programming functions have been preset at the factory. Unless a change is advised by your dealer, it is
NOT necessary to enter Master Programming Mode.
1. Regeneration Time (r)
- The time of day at which regeneration may take place is designated by the letter "r".
- Default regeneration time setting is 12A
- The first display digit indicates A.M. or P. M. To change the value, press the Set/Change button.
- Press Menu/Enter button to accept the value and move to the next digit.
- The second and third display digits indicate the hour at which the regeneration will occur.
- Change the digits with the Set/Change button and accept with the Menu/Enter button.
- After the entire display flashes, press the Menu/Enter button to move to the next menu item.
2. Backwash Cycle Step Times* (Steps 2, 3, 4, 5)
Example ( 3 - 20 )
- The next 4 displays set the duration of time in minutes for each backwash cycle step.
- The step number which is currently modifiable is indicated on the far left of the display screen.
- The number of minutes allotted for the selected backwash step is displayed on the far right.
- Change the digit values using the Set/Change and Menu/Enter buttons as described above.
Note on Air Draw Cycle (4):
The longer the unit is set to remain in the Air Draw cycle (4), the more air is drawn into the system. A default
setting of 20 minutes draws air down to the level of a normal media bed height. If the system needs more air,
increase the time setting for step (4) or decrease the number of days between air draw cycles.
3.
Bluetooth Enabled
4.
Bluetooth Password
- To change digit value, press the Set / Change button.
- To accept the digit value, press the Menu / Enter button.
- Next digit will flash to begin setting.
- Once the last digit display is accepted, all digits will flash.
5. To Exit the Master Programming Mode, press the Menu / Enter button until time of day returns.
Note: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.
Example (r12A)
1 (ON)
BE
0 (OFF)
BE
BtPP is displayed for one second, then password is displayed.
Programming the Control Valve
Example ( A)
13