Page 2
IMPORTANT SAFETY INSTRUCTIONS 14. REFER all servicing to qualified service personnel. Servicing is required when the ap- paratus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been READ these instructions.
Page 3
IMPORTANTES INSTRUÇÕES DE SEGURANÇA 13. DESLIGUE este aparelho da tomada elétrica durante tempestades com relâmpagos ou quando não seja utilizado por longo período. 14. DEIXE toda a manutenção sob a responsabilidade de uma equipe de manutenção LEIA estas instruções. qualificada. É necessário realizar a manutenção quando por algum motivo o aparelho GUARDE estas instruções.
AXT630, AXT631 and AXT632 Antenna Distribution Systems Antenna Distribution Systems send the RF signal from a single pair of antennas to multiple receivers. Ultra-linear amplification and adjustable attenuation optimize performance in difficult RF environments. Selectable input filters match the available frequency bands of transmitters, providing extra protection from strong out-of-band signals.
Controls and Connectors power AXT631 606-814 MHz Antenna Distribution Ampli er AXT631 RF outputs RF outputs antenna PoE Class 1 ① LCD Display ⑨ Network status LED (green) Displays menu and settings. • Off = no network link • On = network link active ②...
Installing Remote Antennas Remote antennas offer greater flexibility for antenna placements and can improve performance by providing a less obstructed transmission path and extend- ing range. Consult http://www.shure.com for tips and best practices for remote mounting antennas. RF Output Distribution...
Multiple Levels of Antenna Distribution For large configurations, multiple Antenna Distribution Systems can be layered to support several levels of signal distribution: • Two levels of antenna distribution are possible if the level 1 and level 2 Antenna Distribution Systems have the Cascade ports activated •...
To take advantage of design improvements, new versions of the firmware can be uploaded and in- stalled using the Firmware Update Manager tool available in WWB6 software. Firmware is avail- able for download from http://www.shure.com.
Page 10
Specifications -- AXT630, AXT631, AXT632 Dimensions Impedance 44 mm x 483 mm x 366 mm (1.7 in. x 19.0 in. x 14.4 in.), H x W x D 50 Ω Weight Bias Voltage 4.6 kg (10.1 lbs), 12 V DC, 150 mA (300 mA maximum) Housing RF Frequency Range Steel;...
Page 11
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its European representatives. For contact information please visit www.
Page 12
United States, Canada, Latin Asia, Pacific: Europe, Middle East, Africa: America, Caribbean: Shure Asia Limited Shure Europe GmbH Shure Incorporated 22/F, 625 King’s Road Jakob-Dieffenbacher-Str. 12, 5800 West Touhy Avenue North Point, Island East 75031 Eppingen, Germany Niles, IL 60714-4608 USA...