Download Print this page

Specification - Toshiba Density (Consistency) Meter LQ500 User Manual

Toshiba density (consistency) meter user guide
Hide thumbs Also See for Density (Consistency) Meter LQ500:

Advertisement

Table 4. Type Specification Code
(LQ500 Density (consistency) Meter)
TYPE
CAT Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
L Q 5 0 0
A
0 5
0 8
1 0
1 5
2 0
2 5
3 0
B
C
F
A
B
C
A
B
C
D
A
B
C
D
E
X
A B
A C
A D
A E
A F
Note 1: The specification of PED (Pressure Equipment
Directive) is required from 150 to 300 mm (6" to
12") when the installation location is in the Europe.
Note 2: The differences between standard type are RTD
sensor and Applicator window.
Note 3: Toshiba recommends to using our specified cable.
ISO9001 and ISO14001 are certified.
Misuse of this product can result in damages to property or human injury.
Read related manuals carefully before using this product

SPECIFICATION

Microwave Density (Consistency) Meter
Standard
Meter Size
50mm (2")
80mm (3")
100mm (4")
150mm (6")
200mm (8")
250mm (10")
300mm (12")
Mounting Style
JIS 10K flange connection
ANSI 150 flange connection
DIN 16 flange connection
Purpose
Standard
for PED (150 to 300 mm
(6" to 12") for EU) (Note 1)
for UL/CUL Hazardous locations
type
Wetting parts
SCS14A cast (Equivalent to 316L
SS) pipe (standard)
SCS14A cast (Equivalent to 316L
SS) pipe with teflon PFA coating for
sticky application
SCS14A cast (Equivalent to 316L
SS) pipe for abrasive application
(Note 2)
Hastelloy C pipe
Cable length between detector
(RF part) & converter
10 m (32.8 ft) (standard)
20 m (65.6 ft)
30 m (98.4 ft)
40 m (131.2 ft)
50 m (164 ft)
None (Note 3)
Optional specifications
None (standard) (blank codes are
required.)
Pipe buffing type
-20 to 50 deg.C (-4 to 122 deg.F)
environment temperature
specification, 200 to 240 Vac power
supply type of LQ500
Pipe buffing type with -20 to 50
deg.C (-4 to 122 deg.F) environment
temperature specification, 200 to 240
Vac power supply type of LQ500
-20 to 50 deg.C (-4 to 122 deg.F)
environment temperature
specification, 100 to 120 Vac power
supply type of LQ500
Pipe buffing type with -20 to
50deg.C (-4 to 122deg.F)
environment temperature
specification, 100 to 120 Vac power
supply type of LQ500
.
Table 5. Type Specification Code
(AF900 Hand-held Terminal)
Model
Specification Code
1 2 3 4 5 6
7
8
9 10 11 12
A F 9 0 0
L Q 3
A
Table 6. PED matrix
Flange
mm
50
80
inch
2
3
DIN16
SEP
DIN10
ANSI150
SEP
SEP: Not required the PED.
Certified: The PED is certified.
Check your flange type and its meter size of the LQ500
whether it corresponds to the PED or not when its
installing location is in the Europe.
If yes, you need to choose the code "B" at the 10th
column in the specification code (Table 4)
Specifications are subject to change without notice.
LQ500
Description
Hand-held terminal
For use with LQ series
Display language English
A A 3
Standard
Meter Size
100
150
200
250
300
4
6
8
10
Certified
SEP
Certified
Certified
Printed in Japan 2006-11 (TDOC)
© TOSHIBA Corporation 2003
All Rights Reserved.
12
9

Advertisement

loading

This manual is also suitable for:

Lq500