Reporting Ademco Contact ID transmissions

The NX-8E has the ability to report Ademco Contact ID transmissions. Each
report in Contact ID consists of an event code and a zone ID (the number of the
zone that is in alarm). The event codes are described in the following table and
are programmed in the zone type event code (Locations 110 to 169).
Table 15: Reporting Ademco Contact ID transmissions
Event code
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
NX-8E Control Panel Installation Manual
Contact ID
Description
122
Silent panic
110
Fire alarm
120
Panic alarm
130
Burglary alarm
131
Perimeter alarm
132
Interior alarm
133
24-hour burglary
134
Entry alarm
135
Day/night alarm
150
Nonburglary 24-hour
121
Duress alarm
100
Medical alarm
123
Audible panic alarm
137
Tamper alarm
602
Periodic test
151
Gas detected
158
High temperature
154
Water leakage
140
General alarm
140
General alarm
159
Low temperature alarm
158
High temperature alarm
115
Manual fire alarm
Appendix A: Reporting codes