System clock

To set the system clock:
1. Enter *, 9, 7, master code. The Service LED begins flashing.
2. Enter the clock time (military time). Hour: 00 through 23, where 00 is
midnight, 01 is 1:00 a.m., 23 is 11:00 p.m. Minutes: 00 to 59. For example,
3.25 a.m. = 0, 3, 2, 5; and 5:00 p.m. = 1, 7, 0, 0.

User codes

To change the user codes:
1. Enter *, 5, master code. The Ready LED begins flashing.
2. Enter the two-digit user number (for example, 03 for user 3). The maximum
number of users is 99.
3. Enter the new user code designated for that individual. The Ready LED
begins flashing, indicating the code was accepted. If the code was rejected, a
beep sounds three times.
If another user code needs to be programmed, repeat the process.
4. Press # while the Ready LED is flashing to exit the user code programming
mode.

User authority level

To assign user authority levels:
1. Enter *, 6, master code. The Ready LED begins flashing.
2. Enter the two-digit user number. The Ready LED illuminates and the Instant
LED begins flashing.
3. Turn on the LED for the features you want. See Table 5 on page 14 for a
description of each LED.
4. Enter *. The Instant LED will illuminate steady.
5. Now you are in partition enable mode. This tells the system what partition this
user can arm/disarm. LEDs 1 through 8 illuminate for each partition that the
user has authorization for. To change any of these numbers, press 1 through
8 to toggle the corresponding LED off/on, indicating the user is assigned or
not assigned access to that partition.
6. Enter *. This returns you to step 2, where you can enter another user number
to assign attributes for. You may continue this procedure until you have
NX-8E Control Panel Installation Manual