Chapter 2: Reporting codes
assigned authority levels to all user numbers, or you can press # to exit
assigning authority level programming.
Table 5: LED features
LED
Attributes if LED 8 is off
1
Reserved
2
Armed only
3
Arm only after close window
4
Master arm/disarm (can program other
codes)
5
Arm/disarm code
6
Allowed to bypass zones
7
Code sends open/close reports
8
If this LED is on, LEDs 1 to 7 use the
column to the right.
Note:
Any master arm/disarm code can add or change a user code if the master
code has access to the same partitions as the code being added/changed.
Consequently, when programming the user codes for a partitioned system, leave
at least one code (can be go to program code if enabled in Location 43) access
to all partitions or you will not be able to add new users. If you want the end user
to be able to add new codes, you must remove the partition authority from all
blank codes.
Entering *, 9, 8 while the system is disarmed, causes the control panel to do a
callback for a download. A valid user code is required after pressing *, 9, 8 if it is
enabled in Location 41.
Entering *, 9, 9 while the system is disarmed causes the control panel to seize
the phone line for a download. A valid user code is required after pressing *, 9, 9
if it is enabled in Location 41.

Control panel programming

Programming the control panel requires you to enter program mode, select the
module to program, program a location, and then exit the location and program
mode.
14
Attributes if LED 8 is on
Activate output 1
Activate output 2
Activate output 3
Activate output 4
Arm/disarm
Bypass zones
Open/close reporting
If this LED is off, LEDs 1 to 7 use the
column to the left.
NX-8E Control Panel Installation Manual