R
epair
[3] DISASSEMBLY/ASSEMBLY
[3] -6. Main Switch Section
DISASSEMBLING
Note: Main switch consists of Micro switch (On/off switch),
Reverse switch and Switch cover.
After removing F/R change lever, unscrew the screw that
fastens Micro switch to Reverse switch.
Main switch section can now be removed from Housing R
by pulling Micro switch in the direction of the gray arrow
while turning it counterclockwise. (Fig. 28)
ASSEMBLING
1) Assemble Micro switch to Reverse switch by fastening
the screw to the recommended torque of 0.29 - 0.34N.m.
2) Fitting the boss of Reverse switch in the concave portion
of F/R change lever, assemble F/R change lever to
Reverse switch. (Fig. 29)
3) Assemble Main switch section to Housing (R).
Fig. 28
F/R change lever
Switch cover
Micro switch
(On/off switch)
screw
Fig. 29
concave portion
of F/R change lever
P 11/15
Reverse switch
boss of Reverse switch