Motor Housing; 230V Electrical Schematic - Titan Elite E15 Series Owner's Manual

Table of Contents

Advertisement

()
Figure SA
ITEM NO PART NO
9
761-045
10
761-244
11
700-639
16
760-027
23
761-201
For 230 Volt Units:
ITEM NO PART NO
23
761-237
24
761-231
25
761-304
26
765-050
27
770-309
/'-.
11
230V Electrical Schematic
DESCRIPTION
QTY
Outer Housing
1
(Includes #1 0)
Screw
1
Screw
6
Mounting Stud
4
Motor Field Assy. 120V
1
(Does not include #16)
DESCRIPTION
Field Assembly 230V
Armature
Circuit Breaker
Motor Starter
Power Cord
QTY
1
1
1
1
1
19
Figure 5
Motor Housing Replacement
WARNING: Before proceeding, follow the Pressure
Relief Procedure outlined on page 5. Additionally,
follow all other warnings to reduce the risk of an
injection injury, injury from moving parts or electric
shock. Always unplug the sprayer before servicing!
1. Follow steps 1 through 6 in Armature Replacement.
2. Remove Switch cover plate (#37) and Insulator Plate
(#38). See Figure 6.
3. Disconnect black wire from Post (#2) of Motor Starter
(#42).
4. Disconnect black wire from Motor to white wire from
Power Cord.
5. Remove outer Motor Housing (#9).
6. Loosen set screw (#1 0) and push Motor Field Assembly
(#23) out from the back of the outer Motor Housing {#9).
7. Inspect Motor Field Assembly (#23). If damaged,
replace.
8. To install Motor Housing, reverse steps 1 through 6
here and steps 1 through 6 of the Armature Replacement.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents