6-6 Communications Settings
6-6-5

Setting the Controller Link Network

If using a Controller Link Network is enabled for the project, settings for the network will be
displayed on the right side of window. Set the node address and baud rate (Comm. Speed).
Click the Write Button after setting these items. The Controller Link is supported by the NS12
and NS10 PTs only, and is not supported by the NS8 PTs.
• Setting Communications Conditions for the Controller Link Network
Network Add.
Node Address
Comm. Speed
Read Status
Read Allocation
Add.
Note: Using the Controller Link network and the network number cannot be changed at the PT. If you
6-38
Item
Displays the network address
used for Controller Link.
Sets the local node address.
Sets the baud rate.
Displays whether Controller Link status is read (display
only).
Displays address where status is read (display only).
change the setting, display the communications settings in the CX-Designer by selecting PT –
Communication Setting, change the setting, and then transfer the project to the PT.
Function
Display only
1 to 32
500K, 1M, or 2M
Setting