Cleaning and care
Cleaning the drum, suds
container and drainage system
The drum, suds container, and drainage
system can be cleaned if necessary.
 Start the Clean machine programme.
 Add powder detergent to the 
compartment in the detergent drawer.
 At the end of the programme, check
the inner drum and remove any
coarse residues.
Use the Clean machine programme
regularly if you frequently use
disinfection programmes.
Cleaning the filters in the water
inlet
The washing machine has filters to
protect the water inlet valves. Check
these filters about every 6 months or
more often if there are frequent
interruptions to the external water
supply.
Cleaning the filters in the inlet hoses
 First turn off the tap.
 Unscrew the inlet hose.
 Remove the rubber seal from the
recess.
 Using combination or pointed pliers,
take hold of the plastic filter bar and
remove the filter.
 Clean the plastic filter.
 Reassemble the filter and seal in the
reverse order and reconnect the
hose.
44
Make sure there is no water leaking
from the threaded union.
Tighten the threaded union.

Cleaning the filters in the water inlet

valves
 Using pliers, carefully loosen the
ribbed plastic nut on the inlet valve
and unscrew.
 Withdraw the filter at the bar with
pointed pliers and rinse it clean under
running water. Reassemble the filter
and seal in the reverse order and
reconnect the hose.
Replace the filters after cleaning.