Flow Diagrams - Culligan CSM Series Installation, Operating And Service Instructions

Table of Contents

Advertisement

Flow Diagram - Service Step (Home Position)
1.
These diagrams illustrate the simplicity of the Brunermatic valve and positive control of flow direction.
2.
Note that only diaphragm valves 1 & 4 are open and flow is directed to top of resin tank, through resin bed, out
bottom of tank into service line.
3.
Pressure is directed to pilot valve which distributes pressure to other valves.
4.
Pressure is also directed through the brine injector ports to the brining assembly in brinemaker, where proper
liquid level is maintained.
SERVICE
Position
Dial
Cat. No. 01016370
Injector
Pilot Strainer
Hard
5
Water
Inlet
1
17
Soft
Water
2
Outlet
4
Sample
Cock
Figure 1. Service

Flow Diagrams

Soft Water
Hard Water
Brine
Resin
Supporting Bed
Flow Diagrams
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents