C.b. Functions - Immergas LUXOR Series Manual

Pellet boilers
Table of Contents

Advertisement

LUXOR
22
No ignition.
If the flame does not start during the ignition phase, or the flue
gas temperature does not reach an adequate value in the time
set for ignition, the boiler with switch off and "ALAR NO ACC"
will appear on the display.
Press the "On/Off " button to reset the alarm.
Wait for the cooling cycle to complete, clean the brazier and
proceed with ignition once again.
Switch-off during the work phase.
This happens in the event of unexpected boiler switch-off during
normal operation (for example, pellet finished in the tank or due
to a pellet loading gearmotor fault).
The boiler continues to operate until any pellet in the brazier
have finished burning, then "ALAR NO FIAM" will appear on
the display and the boiler switches off.
Press the "On/Off " button to reset the alarm.
Wait for the cooling cycle to complete, clean the brazier and
proceed with ignition once again.
These alarms are to signal that before ignition, you must make
sure the brazier is completely free, clean and placed correctly.
Blackout.
If there is a blackout for a few seconds, when the mains voltage
is restored, the boiler immediately returns to the operating state
it had before the blackout.
If there is a blackout long enough for the flue gas temperature to
drop below the reference value threshold (55 °C), when restored,
the boiler shuts down and "ALAR NO FIRE" is displayed.
System pressure safety.
System pressure is electronically controlled and must be between
0.5 and 2.3 bar. If this is not so, the boiler will trigger an alarm
and "ALAR PRESS" will be displayed.
Check system pressure by pressing
bar value will be displayed in the top display.
In any case, the safety valve ensures that 2.5 bar is not exceeded
by automatically venting excess water outside.
P.C.B. FUNCTIONS
Antifreeze function.
If the probe installed inside the boiler detects water temperature
below 5 °C, it automatically enables the circulation pump in
order to prevent system freezing.
Pump anti-block function.
In case of prolonged inactivity of the pump, it is enabled for 10
seconds at regular intervals in order to prevent it from blocking.