INDEX MAIN INDEX 1 LUXOR DESCRIPTION..................................4 2 LUXOR FEATURES ....................................5 3 QUALITATIVE FEATURES OF THE PELLET ..........................7 4 LUXOR 16 MAIN DIMENSIONS .................................8 5 LUXOR 20 - 24 MAIN DIMENSIONS ..............................9 6 LUXOR 28 - 33 MAIN DIMENSIONS ...............................10 7 HYDRAULIC CONNECTIONS TO THE SYSTEM .........................11 8 ANTI-CONDENSATION VALVE KIT CONNECTION (OPTIONAL) ..................12 9 INSTALLATION ROOM FEATURES ..............................13 10 MINIMUM INSTALLATION DISTANCES AND PROVISIONS....................14...
LUXOR DESCRIPTION LUXOR is the range of floor standing pellet boilers proposed by Immergas for room central heating / C.H. systems and for the production of DHW, with fan assisted open chamber with wide flame/power modulation range, ideal for new, redevelopment or in place of obsolete solid fuel generators.
LUXOR LUXOR FEATURES Range of pellet boilers formed by 5 central heating / C.H. models • High efficiency heat exchanger characterised by wide water for open room base central heating and high performance fan passages and relative low clogging risks; assisted (type B ), (up to 92.1% ref.
Page 6
LUXOR • Low power consumption system circulator, preset as standard; • Automatic air vent valve; • Insulation with 30 mm thickness non-allergenic synthetic wool around the heat exchanger body; • Variable speed suction fan, electronically controlled by inverter board; • Automatic pellet conveyor auger controlled by P.C.B.; •...
For the Immergas boilers only use with 6mm diameter, 30 mm long pellets having maximum 6% humidity. Store the pellets away from sources of heat, and not in humid areas or explosive environments.
LUXOR LUXOR 16 MAIN DIMENSIONS SYSTEM SYSTEM RETURN FLOW KEY: REF. Description System flow System return Pressure discharge valve Combustion air intake Flue gas exhaust Position of main power supply switch Control panel Water temperature probe Thermostat...
LUXOR LUXOR 20 - 24 MAIN DIMENSIONS SYSTEM SYSTEM RETURN FLOW KEY: REF. Description System flow System return Pressure discharge valve Combustion air intake Flue gas exhaust Position of main power supply switch Control panel Water temperature probe Thermostat...
LUXOR LUXOR 28 - 33 MAIN DIMENSIONS SYSTEM SYSTEM RETURN FLOW KEY: REF. Description System flow System return Pressure discharge valve Combustion air intake Flue gas exhaust Position of main power supply switch Control panel Water temperature probe Thermostat...
LUXOR HYDRAULIC CONNECTIONS TO THE SYSTEM Position of safety valve drain The LUXOR 16-20-24-28-33 models are created to work with (LUXOR 16) closed vessel systems (the vessel itself is standard supplied with the generator, capacity 8 litres). ATTENTION: wanting to create open vessel systems, it is nec- essary to ensure that the minimum pressure switch (calibrated at 0.6 bar) does not intervene.
LUXOR ANTI-CONDENSATION VALVE KIT CONNECTION (OPTIONAL) It is essential for these types of boilers to mount a mixing valve calibrated at 56 °C (see optional kit); this prevents the return of water too cold in the boiler, thus preventing the forming of condensate and corrosion, which inevitably cause a rapid deterioration of the thermal exchange surfaces, thus extending the life of the boiler.
LUXOR INSTALLATION ROOM FEATURES For all information and any further clarifications, refer to Stand- ard UNI 10683:2012. In the event of installation with other central heating appliances, provide for suitable air inlets for each of them (according to the instructions of each product). It is not permitted to install the product in residential spaces: - that have appliances supplied with liquid fuel with continuous or discontinuous operation that take combustion air from the...
LUXOR MINIMUM INSTALLATION DISTANCES AND PROVISIONS Observe the following instructions: - the boiler must be connected to a central heating system and/ or production network of domestic hot water, in compliance with its performance and power; - it is necessary to also consider all national, regional, provincial and municipal laws and regulations of the country of instal- lation of the appliance;...
LUXOR FLUE EXHAUST CONNECTION Connection between the appliance and the flue must be made with a flue exhaust duct compliant with EN 1856-2. For proper operation, the length of the sub-horizontal section must not exceed 2 m, with a minimum slope of 3% and with a maximum number of three 90°...
LUXOR CONNECTION TO THE CHIMNEY The chimney is very important for correct operation of a solid - be made with waterproof materials against flue gas, conden- fuel appliance. sate, thermally insulated and suitable to withstand normal A qualified technician must check the chimney’s efficiency. mechanical stress over time;...
Page 17
LUXOR Chimney dimensioning. Chimney pot. The negative pressure (draught) of a chimney also depends on its height. Check that a windproof chimney pot is installed according to The chimney must be sized to ensure a draught between 8 Pa the regulations in force. and 15 Pa.
LUXOR DRAUGHT REGULATOR (OPTIONAL) The draught regulator (optional kit to be placed in the appliance installation room), constantly compensates for possible draught variations inside the chimney, as the outdoor atmospheric con- ditions change. Operation: when the negative pressure exceeds the desired value (settable on the regulator in Pa), the draught regulator flue adjusting device automatically opens and allows air to enter the duct.
LUXOR OPERATING PRINCIPLE The high combustion quality is guaranteed by an electronic At first ignition or re-ignition after a switch-off for reaching the microprocessor that regulates and optimises the fuel inlet (6 temperature, there is an incandescent electrode which allows to mm pellet) that, falling from the main tank, flows into a worm fully automatically ignite the flame.
LUXOR FEATURES OF THE INTEGRATED PELLET TANK (123 Litres) (123 litri) (123 litri) (123 Litres) 80 kg 80 kg EN plus A1 EN plus A1 EN plus A1 EN plus A1 (70 Litres) (92 Litres) (92 litri) (92 Litres) (92 litri) (70 litri) 60 kg 60 kg...
LUXOR LUXOR 16 TECHNICAL DATA LUXOR 16 Maximum heat input 16.1 Nominal heat output 14.6 Minimum heat output CO emissions ref. to 13% O mg/Nm Primary particulate (PP) ref. to 13% O mg/Nm Efficiency at nominal output 91.0 Efficiency at minimum output 91.2 Degree of efficiency Pellet tank capacity...
Page 22
LUXOR 16.1 LUXOR 20 - 24 TECHNICAL DATA LUXOR 20 LUXOR 24 Maximum heat input 19.00 23.80 Nominal heat output 17.51 21.51 Minimum heat output 5.18 5.20 CO emissions ref. to 13% O mg/Nm 14.0 19.4 Primary particulate (PP) ref. to 13% O mg/Nm Efficiency at nominal output 92.13...
Page 23
LUXOR 16.2 LUXOR 28 - 33 TECHNICAL DATA LUXOR 28 LUXOR 33 Maximum heat input 27.17 31.80 Nominal heat output 24.50 29.10 Minimum heat output 6.34 6.35 CO emissions ref. to 13% O mg/Nm 17.3 24.0 Primary particulate (PP) ref. to 13% O mg/Nm 10.1 Efficiency at nominal output...
LUXOR AVAILABLE HEAD FLOW RATE GRAPHICS 1000 1100 Flow rate l/h The LUXOR models are supplied with a low power consumption circulator. Treating the feed water allows you to prevent problems and In order to prevent this from happening, you are recommended maintain the functionality and efficiency of the generator over time.
LUXOR SYSTEM MINIMUM WATER CONTENT AND PUFFER PROBE The role of the puffer is to fulfil and meet the heat demand A technician’s menu is provided - with access code - to pro- gram the puffer’s temperature (minimum values are usually peaks of the central heating system, thus reducing the ignition and switch-off cycles, thus increasing the degree of efficiency 60÷65 °C).
LUXOR CONTROL PANEL The control panel is supplied together with Example of assembly on the right side the boiler, but it is not assembled. Esempio di montaggio su fianco destro It that can be installed as required, on the side panels, right or left, by removing the knockout panel present.
LUXOR SAFETY DEVICES The LUXOR series boilers are equipped with safety devices that ATTENTION: All LUXOR models are EN 303-5 certified and intervene in case of malfunctions. have overcome the safety tests provided by the standard, hav- It is, therefore, forbidden to tamper with these devices.
Page 30
LUXOR Flue temperature probe: this polarised thermocouple (J type) detects the flue tempera- ture, maintaining operation or stopping the boiler when the flue gas temperature drops below the reference value (55 °C). Automatic vent valve: this valve discharges air inside the boiler. Electric safety: the boiler is protected against sudden current fluctuations (e.g.
LUXOR P.C.B. FUNCTIONS No ignition. Antifreeze function. If the flame does not start during the ignition phase, or the flue If the probe installed inside the boiler detects water temperature gas temperature does not reach an adequate value in the time below 5 °C, it automatically enables the circulation pump in set for ignition, the boiler with switch off and "ALAR NO ACC"...
LUXOR NOTES ON MAINTENANCE AND CLEANING The pellet boiler, like all other products that use solid fuels, When placing the crucible, be precise when checking that its ed- requires simple, thorough cleaning in order to always ensure ges adhere perfectly to their housing and that the hole coincides efficient performance and normal operation.
Page 33
It is only possible to use a suitable dustbuster to vacuum particles of a certain size when the ashes are completely cold. N.B.: Have the Immergas Authorised After-sales Centre per- form a check and maintenance once a year. Cleaning the lower ash drawer.
LUXOR LUXOR PRACTICAL WIRING DIAGRAM mesh filter 230V KEY: Colours of wires: - Auger motor RED - Red - Boiler pump BLK - Black - Flue extraction fan BLUE - Blue - Door switch BRN - Brown ALP - Water thermostat - Yellow / Green ALC2 - Pressure switch WHT - White...
LUXOR OPTIONAL Temperature control OPTIONALS Code CRONO 7 (device class IV* or VII) 3.021622 Seasonal energy efficiency 2%* or 3.5% CRONO 7 WIRELESS (device class IV* or VII) 3.021624 Seasonal energy efficiency 2%* or 3.5% Other OPTIONALS Code Anti-condensation valve kit 3.028491 Draught regulator kit - recommended for LUXOR 16-20- 3.028488...
LUXOR COMBINED STORAGE TANK UNIT FEATURES (PUFFER) 26.1 UB 300 V2 STORAGE TANK UNIT Supply and composition: The UB 300 V2 combi storage tank is a 295 litre thermal storage • 2 coil water/water heat exchangers Ø 32 mm; tank. •...
Page 37
LUXOR Storage tank unit main components. KEY: - Solar panels coil - Domestic Hot Water production coil - Insulating material - Probe holder profile pro lo fermasonde UB 300 V2 Storage Tank Unit technical data. Useful capacity of the storage tank cylinder Domestic hot water side maximum pressure Central heating side maximum pressure Solar circuit maximum pressure...
Page 38
LUXOR 26.2 UB 550 V2 STORAGE TANK UNIT Supply and composition: The UB 550 V2 combi storage tank is a 553 litre thermal storage • 2 coil water/water heat exchangers Ø 32 mm; tank. • Probe-supports; It contains 2 spiral coils for connection of the solar collectors and •...
Page 39
LUXOR Storage tank unit main components. KEY: - Solar panels coil - Domestic Hot Water production coil - Insulating material - Probe-holder pocket - Probe-holder pocket - Probe-holder pocket UB 550 V2 Storage Tank Unit technical data. Useful capacity of the storage tank cylinder Domestic hot water side maximum pressure Central heating side maximum pressure Solar circuit maximum pressure...
Page 40
LUXOR 26.3 UB 750 V2 STORAGE TANK UNIT The UB 750 V2 combi storage tank is a 733 litre thermal storage Supply and composition: tank. • 2 coil water/water heat exchangers Ø 32 mm; It contains 2 spiral coils for connection of the solar collectors and •...
Page 41
LUXOR Storage tank unit main components. KEY: - Solar panels coil - Domestic Hot Water production coil - Insulating material - Probe-holder pocket - Probe-holder pocket - Probe-holder pocket UB 750 V2 Storage Tank Unit technical data. Useful capacity of the storage tank cylinder Domestic hot water side maximum pressure Central heating side maximum pressure Solar circuit maximum pressure...
LUXOR WIRING DIAGRAM EXAMPLE: LUXOR + HEAT PUMP AND SYSTEM MANAGER Expansion Addresses Expansion Addresses Address 4 Contatto che segnala Contact indicating the Supply voltage 24Vac; Alimentazione 24Vac; l’attivazione di LUXOR activation of LUXOR 50Hz 50Hz (da ussostato o termostato (from flow switch or a contatto) contact thermostat)
Page 47
During the useful life of the products, performance is affected by external factors, such as the hardness of the D.H.W., atmos- pheric agents, deposits in the system and so on. The declared data refers to new products that are correctly installed and used in accordance with applicable regulations. N.B.: correct periodic maintenance is highly recommended.
Page 48
Immergas TOOLBOX The App designed by Immergas for professionals Disponibile su Disponibile su Disponibile su To request further specific details, sector Professionals can also use the following e-mail address: consulenza@immergas.com UNI EN ISO 9001:2008 SISTEMA DI QUALITÀ CERTIFIED QUALITY CERTIFICATO...