PARTS REQUIRED:
x1
3/8 x 48 x 72" (1 x 121,9 x 182,9 cm)
3
Place panel with primed side up onto frames with a 3/4" gap as shown.
Maintain flush to top of frame edge.
Ensure 3/4" gap between top, middle and bottom of frames. Hold the measurements and
4
secure with 2" (5,1 cm) nails 6" (15,2 cm) apart.
3-1/2"
(8,9 cm)
15-1/4"
(38,7 cm)
35-1/4"
(89,5 cm)
Primed
side up

BACK WALL PANELS

(15,2 cm)
Flush
12"
(30,5 cm)
3-1/2"
(8,9 cm)
3/4" GAUGE
BLOCK
6"
Flush
CWA
3/4" (1,9 cm)
CXA
3/4" (1,9 cm)
XY
3/4"
(1,9 cm)
3/4" GAUGE
BLOCK
21
x26
2" (5,1 cm)
Use Gauge Block As Spacer
3/4" (1,9 cm)
Use Gauge Block As Spacer
3/4" (1,9 cm)