Appendix; Cables 100Base-Tx; Table 14: Rj-45 Cables; Table 15: Cable Configuration - WAGO ETHERNET Accessories 852 852-0111 Mounting, Installation And Handling Manual

5 port 100base-tx industrial eco switch
Table of Contents

Advertisement

32
List of Figures
8

Appendix

8.1
RJ-45 Cables 100BASE-TX
When connecting your network devices, use a standard Category 5 cable for a
10BASE-T configuration for 100BASE-TX. The pin assignments are as follows:

Table 14: RJ-45 Cables

Contact
1
2
3
4
5
6
7
8

Table 15: Cable Configuration

Application
Switch to
switch or network
adapter
Terminal device
to switch
Comment
The Industrial-ECO-Switch provides Auto-MDI/MDI-X and the NWay function at
the RJ-45 port.
Manual
Version 1.2.0, valid from FW/HW Version 01/06
852-0111 5 Port 100BASE-TX Industrial ECO Switch
Description
TD+
TD-
RX+
N/A
N/A
RX-
N/A
N/A
Cable Type
Straight-through
cable
Crossover cable
WAGO ETHERNET Accessories 852
Pair
2
2
3
1
1
3
4
4
Application
Switch
End
1
2
3
6
Switch
End #1
1
2
3
6
Color
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown/
Brown
Hub
1
2
3
6
Converter
End #2
1
2
3
6

Advertisement

Table of Contents
loading

Table of Contents