Shutting Down The System; Closing Down The System - Schaudt Electroblock EBL 220-4 A Instruction Manual

Table of Contents

Advertisement

Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
811.592 BA / EN
Fault
12 V power supply in the
12 V power supply in the
living area does not work
g
The Electroblock cannot
The Electroblock cannot
be operated from the
be operated from the
DT/LT ... control and
switch panel
If the device becomes too hot due to excessive ambient temperature or
Y
lack of ventilation, the charging current is automatically reduced. How-
ever, always prevent the device from overheating.
If the automatic shutdown mechanism of the battery monitor is triggered,
Y
fully charge up the living area battery.
* For faults regarding the D+--signal, the position of the D+--switch (see
Y
Fig. 3, Pos. 13) has to be checked. Ask your dealer, if required.
3.4

Shutting down the system

Activate the battery isolation on the DT/LT ... control and switch panel
(see instruction manual for the associated control and switch panel).
The heater system's frost protection valve opens when the living area
Y
battery is isolated from the Electroblock by the battery isolation. The boi-
ler and the water tank are emptied when the frost protection valve is ope-
ned. For more information, see the instruction manual of the heater sy-
stem.
3.5

Closing down the system

ATTENTION!
Y
Total discharge!
Damages the living area battery:
The living area battery must be fully charged before closing down and
F
before restarting the system. (Vehicle with an 80 Ah battery must be
connected to the mains supply for at least 12 hours and a 160 Ah
battery for up to 24 hours.)
Possible causes
12 V main switch for living
12 V main switch for living
area battery is switched off
y
Activate the battery isola-
tion on the DT/LT ... con-
tion on the DT/LT
trol and switch panel
Defective fuse or wiring
Defective fuse or wiring
Defective Electroblock
Defective Electroblock
Defective Electroblock
Defective DT/LT ... control
and switch panel
Issued: 21.06.2010
Remedy
12 V main switch for living
12 V main switch for living
area battery must be
y
switched on
Deactivate the battery
con
isolation on the DT/LT
isolation on the DT/LT ...
control and switch panel
Have the fuse and wiring
Have the fuse and wiring
checked
Call customer service
Call customer service
Call customer service
Disconnect the BL. 10/BL.
13 plug from the
Electroblock and plug in
Electroblock and plug in
the emergency plug.
Have the DT/LT ... control and
switch panel repaired.
7