Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
Step switch
Solar charger operation
4
The 12 V main switch (see the instruction manual for the associated control
and switch panel) switches all consumers and the control and switch panel
on and off.
Exceptions:
Frost protection valve
F
Heater
F
Step
F
Gas alarm/waste water valve
F
Power circuit 4
F
Waste-water tank heating
F
For more information, see the DT/LT ... control and switch panel instruction
manual.
ATTENTION!
Y
The self-resetting fuse can trip!
Overcurrent cut-out:
Only press the step switch briefly.
F
Wait approx. 1 minute before pressing the step switch again so that the
fuse can reset itself.
ATTENTION!
Y
Battery buffer function missing!
The connected devices will be damaged:
Never run the solar charger without a battery being connected.
F
3.2

Changing the battery

ATTENTION!
Y
Wrong battery type or incorrectly connected battery!
Will damage the battery or the devices connected up to the Electroblock:
Batteries shall only be changed by qualified personnel.
F
Follow the instructions of the battery manufacturer.
F
The Electroblock is to be used solely for connecting the 12 V power
F
supply to 6-cell lead-gel or lead-acid batteries. Never use unapproved
types of battery (e.g. NiMH batteries).
Only batteries of the same type and capacity should normally be used,
Y
i.e. same as those installed by the manufacturer.
You can change over from lead-acid to lead-gel batteries. You cannot
Y
change over from lead-gel to lead-acid batteries! Your vehicle manufactu-
rer will provide you with information about this.
Issued: 21.06.2010
Fold-away bed
F
Awning light
F
Awning
F
Aerial
F
AES/compressor refrigerator
F
Fridge controller
F
811.592 BA / EN