Schaudt Electroblock EBL 220-4 A Instruction Manual page 6

Table of Contents

Advertisement

Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
Emergency operation
6
The following functions are protected by self-resetting fuses too:
Current measurement
F
Illumination control and switch panel
F
Main Switch
F
When faults expected in these functions, disconnect the electroblock com-
pletely from 12 V for approx. 1 min (best: disconnecting the battery poles).
Please contact our customer service address if you cannot eliminate the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the Electroblock
repaired at a specialist workshop. In this case you must ensure that the
warranty is not invalidated by incorrect repairs being carried out and Schaudt
GmbH will not accept any liability for damage resulting from such repairs.
If a fault has been caused by a defective DT/LT ... control and switch panel it
is always possible to run emergency power via the emergency plug. This is
attached to the instruction manual.
Fault
Living area battery is not
Living area battery is not
charged during 230 V
g
g
operation (battery voltage
permanently below
permanently below
13.3 V)
Living area battery over-
loaded during 230 V
operation (battery voltage
permanently above
14.5 V)
Starter battery is not
Starter battery is not
charged during 230 V
g
g
operation (battery voltage
permanently below
permanently below
13.0 V)
Living area battery is not
charged whilst driving
g
g
(b tt
(battery voltage below
lt
b l
13.0 V)*
Living area battery is over-
loaded whilst driving (bat-
tery voltage permanently
above 14.3 V)
The fridge does not work
whilst driving*
g
Solar charger does not
Solar charger does not
work (power supply and
engine are off)*
engine are off)*
Issued: 21.06.2010
Possible causes
No mains voltage
No mains voltage
Defective Electroblock
Defective Electroblock
No mains voltage
No mains voltage
Defective Electroblock
Defective alternator
No voltage at D+ input
Defective Electroblock
Defective alternator
No power supply to the
fridge
Defective Electroblock
Defective fridge
Solar charger not plugged
Solar charger not plugged
in
Defective fuse or wiring
Defective fuse or wiring
Defective solar charger
Remedy
Switch the cut out in the
Switch the cut-out in the
vehicle back on; check the
;
mains voltage
Call customer service
Call customer service
Switch the cut out in the
Switch the cut-out in the
vehicle back on; check the
;
mains voltage
Call customer service
Have the alternator
checked
Have the fuse and wiring
checked
Call customer service
Have the alternator
checked
Have the fuse and wiring
checked
Call customer service
Have the fridge checked
Plug the solar charger in
Plug the solar charger in
Have the fuse and wiring
Have the fuse and wiring
checked
Have the solar charger
checked