Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
Changing the battery
Starting up
the system
Flat vehicle fuses
Self-resetting fuses
811.592 BA / EN
Disconnect the battery from the Electroblock by activating the battery
isolation on the DT/LT ... control and switch panel on (see Chapter 3.5 as
well).
Replace the battery.
Check once more to ensure that you have fitted the correct type of
battery afterwards.
DANGER!
Y
Battery selector switch set incorrectly!
Danger of explosion caused by the build up of oxyhydrogen gas.
Set the battery selector switch to the correct position.
F
ATTENTION!
Y
Battery selector switch set incorrectly!
The battery will be damaged.
Set the battery selector switch to the correct position.
F
Disconnect the Electroblock from the mains before resetting the battery
selector switch.
Fig. 1
Battery selector switch
Move the battery selector switch (Fig. 1, Pos. 1) into the relevant position
using a thin object (e. g. ball-point pen):
Lead-gel battery: Set the battery selector switch to "Lead-gel" (Gel).
F
Lead-acid battery: Set the battery selector switch to "Lead-acid"
F
(Säure).
Start the system as instructed in Chapter 3.1.
3.3

Operating faults

The majority of power supply system faults are caused by blown fuses.
The following functions are protected by a self-resetting fuse:
the "Step" output
F
If a fault occurs here, the step must not be operated for approx. 1 min.
These fuses reset themselves automatically within this period.
Issued: 21.06.2010