General Information; Installation - Graco 204355 K Series Instructions-Parts List Manual

Extrusion flo-valve
Table of Contents

Advertisement

General Information

NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the parts drawing,
page 7. Parts included in repair kit 207–160 are
indicated with a
for example (4 ).
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION
HAZARD on page 3.
1. Pump: use a ground wire and clamp as shown in
your separate pump manual.
2. Fluid hoses: use only grounded fluid hoses with a
maximum of 500 feet (150 m) combined hose
length to ensure grounding continuity. Check the
electrical resistance of your fluid hoses at least
once a week. If your hose does not have a tag on
it which specifies the maximum electrical resist-
ance, contact the hose supplier or manufacturer
for the maximum resistance limits. If the hose
resistance exceeds the recommended limits,
replace it immediately.

Installation

3. Air compressors and hydraulic power supplies:
ground the equipment according to the manufac-
turer's recommendations.
4. Flo-valve: ground through connection to a properly
grounded fluid hose and pump.
5. Fluid supply container: Ground according to your
local code.
6. Flammable liquids in the spray area: must be kept
in approved, grounded containers. Do not store
more than the quantity needed for one shift.
7. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
8. T o maintain grounding continuity when flushing or
relieving pressure , hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.

Advertisement

Table of Contents
loading

This manual is also suitable for:

204-355

Table of Contents