Removal
1.
Remove the stylus from its storage slot in the back cover.
2.
Remove the uSD/SIM card slot access cover.
3.
Remove 10 screws. Discard the screws. The screws have a one time use seal. New screws must be used when reinstalling
the bottom housing.
4.
Gently pull the bottom housing away from the unit at the scan engine end as shown.
5.
Disconnect the vibrator motor and supercap cables.
6.
Rotate the bottom housing away from the rest of the unit exposing the I/O flex cable as shown.
7.
Remove the kapton tape over the flex connector latch.
8.
Open the flex connector latch and slide the I/O flex cable out of the connector.
Installation
Installation of the bottom housing is reverse order of removal.
1.
Prior to installing a bottom housing inspect the overmolded seal in the top housing for any signs of damage.
Replace as needed.
2.
Insert the I/O flex cable into the connector and close the latch.
3.
Install a piece of Kapton tape over the latch.
4.
Position the bottom housing over the top housing and reconnect the vibrator and supercap cables.
Supercap cable