Nibe UKV 102 Instalation Instruction

Nibe UKV 102 Instalation Instruction

Buffertank for heating and cooling systems
Table of Contents
  • Všeobecné Informace
  • Seznam Součástí
  • Technické Specifikace
  • Všeobecné Informácie
  • Technické Špecifikácie
  • Technische Daten
  • Общая Информация
  • Перечень Деталей

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10

Quick Links

UKV 102
NÁVOD K OBSLUZE A INSTALACI Akumulační nádrž pro vytápěcí a chladicí systémy
CZ
SK
NÁVOD NA INŠTALÁCIU
GB
INSTALATION INSTRUCTION Buffertank for heating and cooling systems
DE
MONTAGEANLEITUNG
Руководство по установке Аккумулирующий бак для систем отопления и
RU
охлаждения
Akumulačná nádrž pre vykurovacie a chladiace systémy
Pufferspeicher für Heiz- und Kühlsysteme
UKV 102

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UKV 102 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe UKV 102

  • Page 1 UKV 102 UKV 102 NÁVOD K OBSLUZE A INSTALACI Akumulační nádrž pro vytápěcí a chladicí systémy Akumulačná nádrž pre vykurovacie a chladiace systémy NÁVOD NA INŠTALÁCIU INSTALATION INSTRUCTION Buffertank for heating and cooling systems Pufferspeicher für Heiz- und Kühlsysteme MONTAGEANLEITUNG Руководство...
  • Page 2: Všeobecné Informace

    NÁVOD K INSTALACI UKV 102 Všeobecné informace Montáž Nádrž UKV se používá v několika oblastech. Nádrž UKV je vybavena oboustrannými závěsy. Chcete- Nádrž UKV lze používat s externím řízením topného li změnit stranu, na které je umístěna jímka, závěsy lze systému.
  • Page 3 UKV (120) se instaluje jako prostředek na zvýšení objemu a průtoku. Uzavřete všechny přípojky, které se nepoužívají. Pokud hrozí nebezpečí možného nulového průtoku, musí se nainstalovat auto- matický přepouštěcí ventil. Upozornění! Toto jsou přehledová schémata. Aktuální instalace se musí naplánovat podle platných norem. UKV 102...
  • Page 4 Pro větší domy, činžovní domy, průmyslové objekty nebo podobné stavby se zásobníky přiváděného vzduchu. Zásobní nádrž se využívá jako vyrovnávací nádoba pro trubkový výměník přiváděného vzduchu. Spojka T se musí umístit co nejblíže nádrži UKV. Upozornění! Toto jsou přehledová schémata. Aktuální instalace se musí naplánovat podle platných norem. UKV 102...
  • Page 5: Seznam Součástí

    93 SMO 10 94 Čidlo vratného potrubí 95 Typový štítek 99 Ponorný ohřívač/elektrokotel 101 Trubkový výměník přiváděného vzduchu (větrání) 120 UKV ‘ 524 Technické specifikace UKV 102 Objem Max. pracovní tlak (bar) Pracovní teplota °C 5 - 95 Hmotnost UKV 102...
  • Page 6: Všeobecné Informácie

    NÁVOD NA INŠTALÁCIU UKV 102 Všeobecné informácie Montáž Nádrž UKV sa používa v niekoľkých oblastiach. Nádrž UKV je vybavená obojstrannými závesmi. Ak chcete zmeniť stranu, na ktorej je umiestnená nádrž, Nádrž UKV možno používať s externým riadením vykurovacieho systému. V takom prípade tepelné...
  • Page 7 UKV (120) sa inštaluje ako prostriedok na zvýšenie objemu a prietoku. Uzavrite všetky prípojky, ktoré sa nepoužívajú. Pokiaľ hrozí nebezpečenstvo možného nulového prietoku, musí sa nainštalovať automatický prepúšťací ventil. Upozornenie! Toto sú schémy prehľadu. Aktuálna inštalácia sa musí naplánovať podľa platných noriem. UKV 102...
  • Page 8 Pre väčšie domy, činžiaky, priemyslové objekty alebo podobné stavby s o zásobníkmi privádzaného vzduchu. Zásobná nádrž sa využíva ako vyrovnávacia nádoba pre trubkový výmenník privádzaného vzduchu. Spojka T sa musí umiestniť čo najbližšie k nádrži UKV. Upozornenie! Toto sú schémy prehľadu. Aktuálna inštalácia sa musí naplánovať podľa platných noriem. UKV 102...
  • Page 9: Technické Špecifikácie

    93 SMO 10 94 Senzor vratného potrubia 95 Typový štítok 99 Ponorný ohrievač/elektrokotol 101 Trubkový výmenník privádzaného vzduchu (vetranie) ‘ 524 120 UKV Technické špecifikácie UKV 102 Objem Max. pracovný tlak (bar) Pracovná teplota °C 5 - 95 Hmotnosť UKV 102...
  • Page 10 INSTALLATION INSTRUCTIONS UKV 102 General Assembly UKV has several different areas of use. UKV is equipped with reversible hinges. If you want to UKV can be used with external control of the heating change the side on which the plunger pipe is located, the system.
  • Page 11 flow is choked uncontrolled, a UKV tank (120) is installed as a volume and flow increaser. Plug any connections that are not used. An automatic by-pass valve must be installed if there is a risk of potential 0-flow. Note! These are outline diagrams. Actual installations must be planned according to applicable standards. UKV 102...
  • Page 12 The accumulator tank is used as a buffer for the supply air coil. The T-coupling must be positioned as close to the UKV tank as possible. Note! These are outline diagrams. Actual installations must be planned according to applicable standards. UKV 102...
  • Page 13: List Of Components

    89 Flow line sensor 93 SMO 10 94 Return sensor 95 Type plate 99 Immersion heater/electric boiler 101 Supply air coil (ventilation) 120 UKV ‘ 524 Technical specifications UKV 102 Volume liter Max operating pressure (bar) °C Working temperature 5 - 95 Weight...
  • Page 14 MONTAGEANLEITUNG UKV 102 Allgemeines Montage Für UKV existieren unterschiedliche Einsatzbereiche. UKV ist mit drehbaren Aufhängevorrichtungen aus- UKV lässt sich bei der externen Steuerung des Heizsys- gestattet. Um das Tauchrohr auf der anderen Seite zu tems einsetzen. Die Wärmepumpe sorgt in diesem Fall platzieren, können die Aufhängevorrichtungen gedreht...
  • Page 15 Heizungssystem unkontrolliert gedrosselt wird, muss ein UKV-Speicher (120) zur Volumen- und Flussvergrößerung in- stalliert werden. Nicht benötigte Anschlüsse müssen mit Stopfen verschlossen werden. Beim Risiko eines potentiellen Nullvolumenstroms muss ein druckgesteuertes Überströmventil installiert werden. Hinweis: Dies sind Prinzipskizzen. Die tatsächliche Anlage muss gemäß den geltenden Normen geplant und montiert werden. UKV 102...
  • Page 16 Für größere Ein- und Mehrfamilienhäuser, Industriehallen usw. mit großen Zuluftaggregaten. Der Speicher fungiert als Puffer für das Zuluftaggregat. Die T-Rohrkupplung ist so nah wie möglich am UKV-Speicher zu platzieren Hinweis: Dies sind Prinzipskizzen. Die tatsächliche Anlage muss gemäß den geltenden Normen geplant und montiert werden. UKV 102...
  • Page 17: Technische Daten

    31 Hilfsrelais 35 Umwälzpumpe 49 Druckgeregeltes Überströmventil 81 Regelventil 89 Vorlauftemperaturfühler 93 SMO 10 94 Rücklauftemperaturfühler 95 Typenschild 99 Elektroheizkassette/Elektrokessel 101 Zuluftaggregat (Lüftung) 120 UKV ‘ 524 Technische Daten UKV 102 Volumen Max.-Betriebsdruck °C Betriebstemperatur 5 - 95 Gewicht UKV 102...
  • Page 18: Общая Информация

    РУКОВОДСТВО ПО УСТАНОВКЕ UKV 102 Общая информация Установка Бак UKV применяется в нескольких областях. Бак UKV оборудован двухсторонними подвесными Бак UKV применяется с отдельным управлением элементами. Если хотите изменить сторону, на отопительной системы. В таком случае тепловой которой расположена гильза, подвесные элементы...
  • Page 19 не регулируется гашение проточности, бак UKV (120) устанавливается как средство для увеличения объема и проточности. Закройте все неиспользуемые элементы подключения. Если грозит опасность возможной нулевой проточности, необходимо установить автоматический перепускной клапан. Предупреждение! Ниже изображены структурные схемы. Актуальная установка должна быть спланирована согласно действующих норм. UKV 102...
  • Page 20 Для больших коттеджей, жилых многоэтажных домов, промышленных объектов и подобных зданий с резервуарами подаваемого воздуха. Аккумулирующие баки используются как компенсационные баки для трубного теплообменника подаваемого воздуха. Соединитель Т должен быть расположен как можно ближе к баку UKV. Предупреждение! Ниже изображены структурные схемы. Актуальная установка должна быть спланирована согласно действующих норм. UKV 102...
  • Page 21: Перечень Деталей

    Регулирующий клапан Датчик выводного трубопровода SMO 10 Датчик возвратного трубопровода Типовой щиток Погружной нагреватель / электрический котел Трубчатый теплообменник подаваемого воздуха (аэрация) Техническая спецификация UKV 102 Объём л Максимальное рабочее (бар) давление Рабочая температура °С 5 - 95 Вес кг...