8 Drive Parameter Access
8.2

Using the MSG Instruction

Table 8-1 Parameterizing the MSG Instruction
1.
MSG Instruction:
Insert the MSG instruction.
2.
Instruction Tag:
Create a controller scope tag
for the instruction in the Tag tab
of the message configuration
dialog box. This tag contains
the working memory area for
the MSG instruction.
3.
Message Type:
Select the CIP Generic
message type.
4.
Service Type:
Select "Get Attribute Single" to
read and parameter or "Set
Attribute Single" to write the
parameter.
SINAMICS S: Speed control of a S120 with an Allen-Bradley controller
(Compact/ ControlLogix with RSLogix 5000) via EtherNet/IP