Equipment Specification; Ambient Conditions; Emc/Esd And Safety - ABB AFS670 Safety Instructions

Precautions and safety, equipment handling advices
Table of Contents

Advertisement

AFS670 | PRECAUTIONS AND SAFETY
4

Equipment Specification

4.1

Ambient Conditions

The equipment must be stored, transported and operated according to the ambient con-
ditions specified below.
Table 1:
Parameter
- Ambient air temperature
Humidity
Air pressure
Table 2:
Parameter
- Ambient air temperature
Humidity
- Air pressure
4.2

EMC/ESD and Safety

Table 3:
Parameter
Radiated emission
Conducted emission
2019-04-30
Climatic conditions during operation
Climatic conditions during storage
EMC
Specification
Standard
up to 2000 m ASL
0 °C ... +60 °C
(up to 6562 ft ASL +32 °F ... +140 °F)
above 2000 m ASL
0 °C ... +50 °C
(above 6562 ft ASL +32 °F ... +122 °F)
Extended
up to 2000 m ASL
-40 °C ... +70 °C
(up to 6562 ft ASL -40 °F ... +158 °F)
above 2000 m ASL -40 °C ... +60 °C
(above 6562 ft ASL -40 °F ... +140 °F)
Extended with Conformal Coating
up to 2000 m ASL
-40 °C ... +70 °C
(up to 6562 ft ASL -40 °F ... +158 °F)
above 2000 m ASL -40 °C ... +60 ° C
(above 6562 ft ASL -40 °F ... +140 °F)
5 % ... 95 % (non-condensing)
min. 600 hPa (+13123 ft; +4000 m)
max. 1060 hPa (-1312 ft; -400 m)
Specification
-40 °C ... +85 °C
(-40 °F ... +185 °F)
5 % ... 95 % (non-condensing)
min. 600 hPa (+4000 m; +13123 ft)
max. 1060 hPa (-400 m; -1312 ft)
Specification
EN 55032 Class A
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
EN 55032 DC supply connection Class A
FCC 47 CFR Part 15 DC supply connection Class A
EN 61000-6-4 DC supply connection Fulfilled
EN 55032 Telecommunication connections Class A
EN 61000-6-4 Telecommunication connections Fulfilled
EQUIPMENT SPECIFICATION
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents