AFS670 | PRECAUTIONS AND SAFETY
Table 5:
Parameter
Overload current protection on the device Non-replaceable fuse
Peak inrush current
Table 6:
Parameter
Rated voltage
Voltage range including maximum toler-
ances
Connection type
Power loss buffer
Back-up fuse for each voltage input
Overload current protection on the device Non-replaceable fuse
Peak inrush current
Table 7:
Parameter
Ethernet
USB
V.24
Table 8:
Parameter
Signal contact
Grounding
Table 9:
Laser Class
Laser class 1
(according to EN 60825-1)
2019-04-30
Interface Power Supply High Voltage (continued)
Interface Power Supply Lower Voltage
Electrical Interfaces
Other Interfaces
SFP based Optical Signal Interfaces
Specification
< 6 A
Specification
24 V DC ... 48 V DC
18 V DC ... 60 V DC
2-pin terminal block Tightening torque 0.34 Nm (3 lb-in)
min. conductor diameter AWG16 (1 mm²)
max. conductor diameter AWG16 (1.3 mm²)
> 10 ms at 20.4 V DC
Nominal rating: 6.3 A
Characteristic: slow blow
< 7 A
Specification
Voltage: ≤ 3.1V
Current: ≤ 31mA
Voltage: ≤ 5V
Current: ≤ 0.5A
Voltage: ≤ 6V
Current: ≤ 10mA
Specification
Imax = 2 A at Umax = 230 V AC
Screw type M3
Tightening torque 0.34 Nm (3 lb-in)
min. conductor diameter AWG18 (0.75 mm²)
Specification
As the laser protection class 1 is complied, dangerous
radiation cannot be emitted. Thus, special precautions
for failures or laser warnings are not necessary.