Download Print this page

jablotron OS-360A Manual page 2

Outdoor siren

Advertisement

Control panel wiring examples
If wired according to figure 2, the siren sounds and flashes during the
whole period of control panel alarms. The siren also provides an
acoustic confirmation of system setting/unsetting. The flashing stops
simultaneously with the sound and ready-state indication is provided –
1x flash in every 45 sec, independently of the system status.
JA-80K
PGX function programmed to
ABC/AB/anything set
Fig. 2 Connection to the JA-80K control panel
If wired according to figure 3, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. The flashing stops
simultaneously with the sound and ready-state indication is provided –
1x flash in every 45 sec, independently of the system status.
JA-82K
PGX function programmed to
ABC/AB/anything set
Fig. 3 Connection to the JA-82K(R,C) control panel
If wired according to figure 4, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. Both acoustic confirmation of
system setting/unsetting and ready-state indication are provided – 1x
flash in every 45 sec, independently of the system status.
JA-65K
PGX
set to
ARM
Fig. 4 Connection to the JA-65K control panel
OS-360A / OS-365A outdoor siren
OK
NC/NO
FLASH
OS-365A
1k
OK
NC/NO
FLASH
OS-365A
1k
OK
NC/NO
FLASH
OS-365A
2k2
If wired according to figure 5, the siren sounds and flashes during
power supply faults, with the sound continuing for just 3 more seconds
from the moment the power supply is restored. The flashing stops
simultaneously with the sound.
No confirmation of system setting/unsetting and no ready-state
indication is provided.
JA-63K
Fig. 5 A simplified two-wired siren-connection
Maintenance
The siren does not need any special maintenance. The NiCd battery
lifetime is about 3 years, depending on the working conditions.
Specialized auto-recharge mode keeps the battery in optimum state. If
the power supply (+12V and GND) is disconnected for a significantly
long period of time, then also disconnect the battery. It is
recommended to perform siren battery checking within general security
system testing – you can check the battery remotely without any direct
access to the siren.
Note: Whenever you handle any of the terminals (e.g. 12V
disconnection) disconnect the battery to avoid siren activation.
Important: An activation of the siren with a disconnected sounder
(see Fig. 1) does not cause any damage to the electronic circuits.
Instead, a high voltage is produced on the sounder connector.
Specification
Power supply
Standby consumption
Maximum load consumption
Backup battery
Piezoelectric siren (OS-360) sound level
With second piezo-electric siren (ACM-OS360)
Electro-acoustic siren (OS-365) sound level
Siren timer
Flasher time
Resistance of the tamper loop
Enclosure
Security grade 2
Working environment
Operational temperature
EMC
Safety
Dimensions
JABLOTRON ALARMS a.s. hereby declares that the
OS-360A/OS-365A is in a compliance with the relevant
Union harmonisation legislation: Directives No: 2014/35/EU,
2014/30/EU, 2011/65/EU. The original of the conformity
assessment can be found at www.jablotron.com - Section
Downloads.
Note: The NiCd backup battery contains cadmium (Cd).
Dispose of batteries safely depending on battery type and
local regulations. Although this product does not contain any
harmful materials we suggest you return the product
to the dealer or directly to the manufacturer after use.
2 / 2
OK
NC/NO
FLASH
OS-365A
10 to 15 V DC
< 50 mA / 12 V
< 800 mA /12 V
NiCd pack 4.8 V / 1800 mAh
Lifetime approx. 3 years
113 dB / 1 m
118 dB / 1 m
110 dB / 1 m
max. 5 minutes
alarm duration +15 minutes / 0
< 70
IP 34D
EN 50131-1, CLC/TS 50131-4
class IV, outdoor general
-25 to +60°C
EN 50130-4, EN 55022
EN 60950-1
230 x 158 x 75 mm
MGZ52203

Advertisement

loading

This manual is also suitable for:

Os-365a