3. Class A Metal Chimney

EXISTING
METAL
CHIMNEY
SYSTEM
DIRECT
VENT PIPE
Figure 5.20
!
Ensure that existing chimney is functionally sound and
clean.
• Have inspection done by qualified chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
Step 1 - Remove existing chimney cap.
Step 2 - Measure the distance from the top of the chimney
to the bottom of the ceiling support box, add 3 in. (76mm) to
this measurement, and cut a section of 4 in. (101mm) flex
pipe to that length (the flex should be fully extended).
Step 3 - Connect the end of the flex pipe section to the
underside of the top adapter, using four sheet metal screws
(Figure 5.21).
Flex
Pipe
Figure 5.21
20
TERMINATION
CAP
TOP
ADAPTOR
FLASHING
4 in. (102mm)
FLEX PIPE
RETRO
CONNECTOR
CAUTION
Top Adapter
Sheet Metal Screws
Quadra-Fire • Hudson Bay Installation Manual_R26 • 01/20
Step 4 - Pass the flex pipe down through the center of the
chimney system, and center the top adapter on the top of
the chimney pipe. Drill four 1/8 in. (3mm) diameter holes
through the top adapter, and into the chimney top. Ensure
that you are drilling into the metal on the chimney. Twist lock
the high wind termination cap onto the top adapter (Figures
5.22 and 5.23).
Figure 5.22
DRILL FOUR 1/8 in.
(3mm) DIAMETER
HOLES
Figure 5.23
Step 5 - Pull the flex pipe down through the ceiling support
box, until it protrudes approximately 3 in. (76mm). Connect
the flex pipe to the retro connector, and attach with sheet
metal screws.
Step 6 - Push the flex pipe back up into the ceiling support
box, center the retro connector, and attach it to the support
box with sheet metal screws.
Step 7 - The connection between the appliance and the
retro connector may be completed with sections of direct
vent pipe.
HIGH WIND
TERMINATION
CAP
SHEET METAL
SCREWS
3-90-7003999