4. Existing Masonry Chimney

Type A - Up & Out Installations for Top Vent
Configurations
Top Adaptor
Retro Connector
90° Elbow
Direct Vent Pipe
Figure 5.24
Page 20
Termination Cap
Flashing
4 in. (102mm)
Flex Liner
Quadra-Fire · Topaz · 7009-113G
Type B - Hearth Rear Vent Installations for Use With
Rear Vent Kit (see Section 12 for conversion kit and
venting components.)
Co-Axial to
Co-Linear Connector
Pipe Length
Optional
Co-Axial to
Co-Linear
Connector
Pipe Length
Optional
Chimney Liner
Termination Cap
3 in. (76mm)
Flex Liner
Chimney Liner
Termination Cap
30 ft. (9m) of 3 in.
(76mm) Flex Liner
Exhaust Section
This section of the
chimney must be
sealed
The chimney must be sealed
from the 4 ft. (1m) section to
termination using a smoke
shelf or a damper.
The seal should be 6 in.
(152mm) below the end of the
4 ft. (1m) Air Intake section.
4 ft. (1m) of 3 in.
(76mm) Flex Liner
Air Intake Section
September 1, 2008